2011-12-28 11:22:31 | 1021 14TH STREET | | PERMIT #11110627 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | THE ADDRESS PROVIDED ON THE PLANS DOES NOT MATCH THE | | ADDRESS PROVIDED ON THE PERMIT APPLICATION. | | | | INDICATE WHERE THIS STAIR WILL TERMINATE IN RELATION TO | | THE ADJACENT EXTERIOR STAIR. | | | | PROVIDE SCALABLE OR DIMENSIONED STAIR, HANDRAIL AND | | GUARD DETAILS. | | | | HANDRAILS AND GUARDRAILS ARE REQUIRED ON BOTH SIDES OF | | THE STAIR. HANDRAIL ENDS SHALL BE RETURNED TO THE WALL | | OR FLOOR OR SHALL TERMINATE AT NEWEL POSTS. | | | | HANDRAIL CROSS SECTION SHALL HAVE A DIAMETER OF NOT | | LESS THAN 1.25-INCHES AND NOT MORE THAN 2-INCHES AND | | SHALL BE CONTINUOUSLY GRASPABLE. | | | | STAIRS SHALL BE SLIP RESISTANT AND HAVE A MINIMUM TREAD | | DEPTH OF 11-INCHES AND PREVENT THE ACCUMULATION OF | | WATER. | | | | WESLEY JOLIN | | WEST PALM BEACH FIRE RESCUE | | FIRE & LIFE SAFETY PLAN REVIEW | | |
|