Date |
Text |
2011-12-12 16:59:54 | SEPARATE PERMITS REQUIRED FOR: |
| LIGHTING (PHOTOMETRIC PLAN TO REFLECT .5 FOOTCANDLE AT |
| RESIDENTIAL PROPERTY LINE AND NO GLARE ON DIXIE, SHOW |
| DETAILS OF FIXTURES, HEIGHT NOT TO EXCEED 15') |
| LANDSCAPE ( NEED MORE TREES ALONG DIXIE AND BEHIND BLDG |
| AT RESIDENTIAL PROPERTY LINE, PALMS NEED TO BE GROUPED |
| IN 3S ONLY 50% SUBSTITUTE FOR TREES, NEED 40" HEDGE |
| MATERIAL AT DIXIE ) |
| PARKING (REVISE PARKING CHART REFLECTING EXISTING,12" |
| INSIDE TO INSIDE STRIPES, NORTH PARKING LOT NO BACK-UP |
| NOTCH REQUIRED, REDUCE DRIVE AISLE IN SOUTH LOT TO |
| INCREASE LANDSCAPING) |
| |
| ADDITIONAL PERMITS REQUIRED FOR: |
| FLAG POLE (SHOW HEIGHT, US OR FL ONLY) |
| DUMPSTER (SHOW DIMENSIONS, MATERIALS) |
| SIGN |
| |
| MISC COMMENTS: |
| INCLUDE DIMENSIONS AND MATERIALS ON CIVIL/SITE PLAN |
| FENCE SETBACK TO BE REFLECTED ON ALL PLANS |
| A/C AND MECHANICAL EQUIPTMENT AND |
| SCREENING...ELEVATIONS AND DETAILS REQUIRED**** VERY |
| IMPORTANT |
| DEFINE SERVICE AREA MATERIAL AREA WITH CAN WASH |
| INDICATE ACCESSIBLE ROUTE TO PUBLIC SIDEWALK |
| SHOW DIMENSION OF ACCESS/CURB AT SOUTH PROPERTY |
| LINE...ONE WAY OR 24'? |
| PROVIDE FDOT PERMIT FOR CURB MODIFICATION |
| |
| QUESTIONS CONTACT FRIEDERIKE MITTNER: 822-1457 |
| FHM SPOKE TO ARCHITECT CAROLINE FOREST 12-12-11 4:15PM |
| EXPLAINED COMMENTS, NEED FOR SEPERATE PERMITS, NEED FOR |
| SCREENING OF A/C AND OTHER ROOFTOP MECHANICAL |
| EQUIPTEMENT. |
2011-12-07 15:35:38 | REVIEW IN PROGRESS...TO BE COMPLETED 12-12-11 FHM |