2011-12-05 17:57:12 | RESIDENTIAL RENOVATION BUILDING REVIEW COMMENTS. |
| 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. |
| |
| 1- ACCORDING TO 2009 REVISIONS SEC. R301.2.1.4.3 THIS |
| BUILDING IS LOCATED ON EXPOSURE "C" NO "B". PLEASE, |
| REVISE CODE & DESIGN LOADS INFORMATION AND THE |
| WINDOWS/DOORS DESIGN PRESSURES ON SHEET A01 OF 5. |
| |
| 2- PLEASE SPECIFY ON PLANS CARBON MONOXIDE ALARMS AS |
| REQUIRED BY SEC. R313.4. |
| |
| 3- PLEASE SPECIFY SMOKE ALARMS ON PLANS AS REQUIRED BY |
| SEC. R313.2.1. |
| |
| 4- PLEASE PROVIDE COMPLETE FRAMING DETAILS AND |
| SPECIFICATIONS FOR THE NEW DOUBLE DOORS AND WINDOWS TO |
| BE INSTALLED. SPECIFY ALL FRAMING MEMBERS SIZES AND |
| FASTENERS AS REQUIRED TO MEET THE DESIGN LOADS OF SEC. |
| R301. |
| |
| 5- PLEASE PROVIDE COMPLETE FRAMING DETAILS FOR EXTERIOR |
| OPENINGS TO BE ENCLOSED AS SHOWN ON PLANS TO MEET THE |
| DESIGN LOADS OF SEC. R301. |
| |
| 6- PROVIDE PRODUCT APPROVALS (2 COPIES) AS REQUIRED BY |
| DCA RULE 9N-3 FOR: |
| A) DOUBLE DOORS AS SHOWN ON PLANS. PRODUCT APPROVAL |
| SUBMITTED IS FOR 8'-0" DOORS. NEED PRODUCT APPROVAL FOR |
| SIZE SHOWN ON PLANS. |
| |
| B) WINDOW MULLIONS AS SHOWN ON PLANS. |
| |
| C) ALL STRUCTURAL CONNECTORS SPECIFIED BY THE ARCHITECT |
| ON THE FRAMING DETAILS. PROVIDE ONLY THE COVER PAGE AND |
| PAGE SHOWING THE CONNECTOR. |
| |
| D) FLAT ROOF AND/OR SHINGLES TO BE INSTALLED. SEE |
| COMMENT #9 BELOW. |
| |
| 7- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING |
| (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC. |
| |
| 8- NEW STEPS BY FLORIDA ROOM: A) PLEASE PROVIDE |
| COMPLETE DIMENSIONS FOR THE LANDING AS REQUIRED BY SEC. |
| R311.4.3. |
| |
| B) PLEASE SPECIFY RISER AND TREADS DIMENSIONS AS |
| REQUIRED BY SEC. R311.5.3. |
| |
| 9- PLEASE CLARIFY SCOPE OF WORK TO BE DONE ON THE ROOF. |
| OWNER IS APPLYING FOR A ROOFING PERMIT ALSO. ARE YOU |
| RE-ROOFING THE HOUSE?. PLEASE COORDINATE WITH ITEM # |
| 6(D) ABOVE. |
| |
| 10- SHEET A01 OF 5: A) PLEASE CLARIFY SCOPE OF WORK |
| NOTE #2. PLANS DON'T SHOW ANY WORK DONE ON THE ENTRY |
| WAY. SEC. 106.1.1 CITY AMENDMENTS. |
| |
| B) CLARIFY SCOPE OF WORK NOTE #4. PLANS DON'T SHOW ANY |
| WORK SHOWING ADDITION OF NEW ENTRY PORTICO. SEC. |
| 106.1.1 CITY AMENDMENTS. |
| |
| C) PLEASE REVISE THE PARCEL CONTROL NUMBER SHOWN ON THE |
| LEGAL DESCRIPTION. NUMBER SHOWN IS INCORRECT. |
| |
| D) PLEASE CLARIFY/REVISE SQUARE FOOTAGES SHOWN AT THE |
| BOTTOM LEFT OF THE PAGE. THIS NUMBERS DON'T MATCH FLOOR |
| PLANS SUBMITTED AND INFORMATION SHOWN ON THE PALM BEACH |
| COUNTY PROPERTY APPRAISER WEBSITE. WHERE IS THE |
| EXISTING SCREEN PORCH?. |
| |