2011-11-03 16:16:03PASSED WITH PROVISOS:
  
 #1 ALL ROW IRRIGATION OR PIPING SHOULD BE INSTALLED IN
 ROW FOR THE PURPOSE
 OF MAINTENANCE AN ACCESSABILITY. (2 1/2" CONDUIT GIVES
 DIRECTION TO INSTALL IN ROW HOWEVER IT IS NOT SHOWN AS
 SUCH.)
 FOR EXAMPLE IN L14
  
 #2 POLES INCLUDED WILL NEED SEPARATE STRUCTURAL PERMIT
 WITH ADDRESSING STRUCTURAL ASPECT AND HURRICANE RATING.
  
 #3 PAVERS AND STAMPED CONCRETE ARE NO IDENTIFIED.
  
 #4 CONCRETE IN THE ROW IS SPECIFIED AS 2500PSI AND 4"
 THINK. OUR CITY STANDARD IS 6" THICK 3000PSI PORTLAND.
  
 #5 SET SUBMITTED IS NOT SIGNED AND SEALED. UPON
 SUBMITTING SIGNED AND SEALED PLANS THEN CSD ENGINEERING
 WILL STAMP AND SIGN.
  