Plan Review Notes For Permit 11090618 |
Permit Number |
11090618 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2011-09-23 17:18:19 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST. | | 2007 FLORIDA RESIDENTIAL CODE W/ 2009 REVISIONS. | | | | 1- ACCORDING TO PROPERTY APPRAISAL WEBSITE (PAPA) THIS | | HOUSE ROOF COVERING IS CONCRETE TILE. PERMIT | | APPLICATION CALLS FOR FLAT ROOF. CLARIFY IF DOING ONLY | | THE FLAT ROOF AREA OF THE HOUSE OR DOING THE ENTIRE | | HOUSE. FLAT ROOF PRODUCT APPROVAL CAN'T BE INSTALLED | | OVER A 2:12 ROOF PITCH. SEC. 106.1.1 CITY AMENDMENTS TO | | FBC. | | | | 2- CLARIFY WHICH FLAT ROOF APPROVED ASSEMBLY IS GOING | | TO BE INSTALLED. PAGES 16 AND 17 OF NOA SUBMITTED ARE | | BOTH HIGHLIGHTED. SPECIFY ONLY ONE APPROVED ASSEMBLY. | | SEC. 106.1.1. | | | | 3- PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING AT | | PERIMETER AND CORNER AREAS AS REQUIRED BY GENERAL | | LIMITATION #7 ON LAST PAGE OF NOA SUBMITTED. THIS | | BUILDING IS LOCATED ON EXPOSURE "C". SEC. R301.2.1.4.3. | | | | 4- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO LOW. | | SEC. 108.3 CITY AMENDMENTS TO FBC. COORDINATE WITH ITEM | | #1 ABOVE. | | | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|