Plan Review Notes
Plan Review Notes For Permit 11090503
Permit Number 11090503
Review Stop B
Sequence Number 1
Notes
Date Text
2011-10-03 13:46:10BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 2007/09 EXISTING BUILDING CODE LEVEL-2
 701.3 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS,
 COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING.
  
 DOOR # 2 & 3 BOTH WILL NEED TO MEET COMPLIANCE WITH:
  
 1) 1008.1.1 SIZE OF DOORS. THE MINIMUM WIDTH OF EACH
 DOOR OPENING SHALL BE SUFFICIENT FOR THE OCCUPANT LOAD
 THEREOF AND SHALL PROVIDE A CLEAR WIDTH OF NOT LESS
 THAN 32 INCHES (813 MM). CLEAR OPENINGS OF DOORWAYS
 WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE
 OF THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES
 (1.57 RAD). WHERE THIS SECTION REQUIRES A MINIMUM CLEAR
 WIDTH OF 32 INCHES (813 MM) AND A DOOR OPENING INCLUDES
 TWO DOOR LEAVES WITHOUT A MULLION, ONE LEAF SHALL
 PROVIDE A CLEAR OPENING WIDTH OF 32 INCHES (813 MM).
  
 2) 11-4.13.5 CLEAR WIDTH. DOORWAYS SHALL HAVE A MINIMUM
 CLEAR OPENING OF 32 INCHES (813 MM) WITH THE DOOR OPEN
 90 DEGREES, MEASURED BETWEEN THE FACE OF THE DOOR AND
 THE OPPOSITE STOP