Date Text
2011-09-21 11:31:53*****PROVISO*****
  
 712.2 VALVES REQUIRED. A CHECK VALVE AND A FULL OPEN
 VALVE LOCATED ON THE DISCHARGE SIDE OF THE CHECK VALVE
 SHALL BE INSTALLED IN THE PUMP OR EJECTOR DISCHARGE
 PIPING BETWEEN THE PUMP OR EJECTOR
  
 712.3.5 EJECTOR CONNECTION TO THE DRAINAGE SYSTEM.
 PUMPS CONNECTED TO THE DRAINAGE SYSTEM SHALL CONNECT TO
 THE BUILDING SEWER OR SHALL CONNECT TO A WYE FITTING IN
 THE BUILDING DRAIN A MINIMUM OF 10 FEET (3048 MM) FROM
 THE BASE OF ANY SOIL STACK, WASTE STACK OR FIXTURE
 DRAIN. WHERE THE DISCHARGE LINE CONNECTS INTO
 HORIZONTAL DRAINAGE PIPING, THE CONNECTOR SHALL BE MADE
 THROUGH A WYE FITTING INTO THE TOP OF THE DRAINAGE
 PIPING.
  