Plan Review Notes
Plan Review Notes For Permit 11090046
Permit Number 11090046
Review Stop ENG
Sequence Number 1
Notes
Date Text
2011-09-27 09:16:11COMMENTS
  
 #1 SURVEY SUBMITTED DOES NOT SHOW THE WORK AREA.
  
 #2 PLEASE SHOW CROSS SECTION OF PROPOSED PAVEMENT
 SHOWING CONCRETE BASE AND PAVEMENT.
  
 #3 STATE PERVIOUS AND IMPERVIOUS CALCULATION OF THE
 SITE INCLUDING IMPROVEMENTS SOT THAT THE CITY CAN
 UPDATE STORMWATER ACCOUNT.
 (2001 SURVEY SUBMITTED IS NOT CURRENT)
  
 #4 PLEASE SHOW HOW STORM CATCH BASINS CONNECT.
  
 #5 THE REQUIRED WATER QUALITY TREATMENT VOLUME FOR WET
 DETENTION IS THE GREATER OF 1 INCH OVER THE ENTIRE
 RIGHT OF WAY OR 2.5 INCHES OVER THE IMPERVIOUS AREA.
 CONSULT WITH YOUR CIVIL ENGINEER.
  
 **************************************
  
 MANUEL JULIAN GONZALEZ
 CSD ENGINEERING REVIEW
 401 CLEMATIS STREET,
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  