2011-08-30 09:49:091450 CENTREPARK BOULEVARD - SUITE #150
 PERMIT #11080665
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 EACH NEW SMOKE OR FIRE-RATED WALL/PARTITION SHALL BE
 PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING READING
 FIRE/SMOKE BARRIER - PROTECT ALL OPENINGS. CHARACTERS
 SHALL BE AT LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN
 STROKE. IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15
 FEET ON CENTER.
  
 PENETRATIONS THROUGH A FIRE-RATED WALL ASSEMBLY SHALL
 BE PROTECTED BY A FIRESTOP SYSTEM OR DEVICE.
  
 PROVIDE TACTILE SIGNAGE AT REQUIRED EXIT DOORS WITH
 EXIT SIGNS.
  
 SHEET A-8: THE COMMON PATH OF TRAVEL INDICATED ON THE
 PLAN EXCEEDS 100 FEET OF LENGTH.
  
 SHEET A-8: TRAVEL DISTANCE TO EXTINGUISHERS EXCEED 75
 FEET.
  
 SHEET E-2: CONFERENCE ROOM #103 AND RECEPTION #101
 EQUIPPED WITH CARD READERS PREVENTING OCCUPANTS FREE
 EGRESS TO A SECONDARY EXIT.
  
 SHEET E-2: EXIT ACCESS CORRIDOR IN SUITE #150 EQUIPPED
 WITH CARD READER ON EGRESS SIDE OF EXTERIOR EXIT DOOR.
  
 SHEET E-2: FOUR FIRE ALARM HORN-STROBE DEVICES SHOWN.
 IT MAY BE DIFFICULT TO MEET THE AUDIBILITY REQUIREMENTS
 OF NFPA 72 WITH ONLY FOUR AUDIBLE DEVICES.
  
 SHEET E-3: NO EXIT SIGNAGE PROVIDED FOR SOUTH OFFICE
 SPACE IN SUITE #165.
  