Plan Review Notes
Plan Review Notes For Permit 11080116
Permit Number 11080116
Review Stop B
Sequence Number 1
Notes
Date Text
2011-08-17 09:30:30BUILDING PLAN REVIEW
 PERMIT: 11080116
 ADD: 4200 N FLAGLER
 CONT: BENCHMARK III CORP.
 TEL: (561)722-5095
  
 2007 FLORIDA BUILDING CODE W/
 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING PROVISO:
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1)THIS PROVISO WAS ATTACHED TO THE FOUNDATION PERMIT.
 INSPECTOR IS TO REVIEW AND BRING IN A SIGNED SEALED
 SOILS REPORT AT TIME OF FOUNDATION INSPECTION. THIS
 PLAN IS FOR A NEW BUILDING PLEASE PROVIDE SOILS REPORT
 FOR THE SAFE MINIMUM SOIL BEARING VALUES. 1802.2.1
 QUESTIONABLE SOIL. WHERE THE SAFE-SUSTAINING POWER OF
 THE SOIL IS IN DOUBT, OR WHERE A LOAD-BEARING VALUE
 SUPERIOR TO THAT SPECIFIED IN
 THIS CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL
 REQUIRE THAT THE NECESSARY INVESTIGATION BE MADE. SUCH
 INVESTIGATION SHALL COMPLY WITH THE PROVISIONS
 OF SECTIONS 1802.4 THROUGH 1802.6 .
  
 2) THIS PROVISO WAS ATTACHED TO THE FOUNDATION PERMIT.
 THE NEW FOUNDATION PLANS DO SHOW WHAT FINISH SLAB
 ELEVATION 100 IS REFERENCED TOO IN NGVD. THIS BUILDING
 IS IN A A- 5 FLOOD ZONE. THE BASE FLOOD ELEVATION FOR
 FINISH FLOOR IS 7.5 NGVD. SHEET AS-101 INDICATES A
 FINISH FLOOR ELEVATION OF 100.00' BUT THERE IS NO
 REFERENCE TO WHAT 100.00' IS EQUAL TO?
  
 3A)FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING,
 PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING
 REPORTS ARE AS FOLLOWS:
 EXTERIOR DOORS GLAZED OR SOLID SINGLE AND DOUBLE
 WINDOWS W/ LARGE MISSILE IMPACT
 WALL LOUVERS
 ROOFING ASSEMBLIES, STANDING SEAM METAL ROOF, PLEASE
 NOTE PLANS INDICATE THE USE OF A SELF-ADHERED MEMBRANE,
 MUST COMPLY WITH PRODUCT APPROVAL IF A NAILABLE SUB
 SHEET IS
 REQUIRED.
  
 3B) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE
 REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 4) NO TRUSS ENGINEERING PACKAGE HAS BEEN SUBMITTED,
 CONTRACTOR IS WORKING AT OWN RISK, SINCE THE MAGNITUDE
 OF GRAVITY, UPLIFT OR LATERAL LOADS HAS NOT BEEN
 PROVIDED BY TRUSS ENGINEER, THE DESIGNER OF RECORD IS
 TO REVIEW & STAMP ENGINEERING BEFORE TRUSS ENGINEERING
 IS SUBMITTED TO THE BUILDING DEPARTMENT FOR REVIEW.
  
 5) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  