Plan Review Notes
Plan Review Notes For Permit 11080083
Permit Number 11080083
Review Stop B
Sequence Number 1
Notes
Date Text
2011-08-04 15:03:22BUILDING PLAN REVIEW
 PERMIT: 11080083
 ADD: 4200 N FLAGLER
 CONT: BENCHMARK III CORP.
 TEL: (561)722-5095
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) THIS PLAN IS FOR A NEW BUILDING PLEASE PROVIDE SOILS
 REPORT FOR THE SAFE MINIMUM SOIL BEARING VALUES.
 1802.2.1 QUESTIONABLE SOIL. WHERE THE SAFE-SUSTAINING
 POWER OF THE SOIL IS IN DOUBT, OR WHERE A LOAD-BEARING
 VALUE SUPERIOR TO THAT SPECIFIED IN
 THIS CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL
 REQUIRE THAT THE NECESSARY INVESTIGATION BE MADE. SUCH
 INVESTIGATION SHALL COMPLY WITH THE PROVISIONS
 OF SECTIONS 1802.4 THROUGH 1802.6 .
  
 2) THIS BUILDING IS IN A A- 5 FLOOD ZONE. THE BASE
 FLOOD ELEVATION FOR FINISH FLOOR IS 7.5 NGVD. SHEET
 AS-101 INDICATES A FINISH FLOOR ELEVATION OF 100.00'
 BUT THERE IS NO REFERENCE TO WHAT
 100.00' IS EQUAL TO?
  
 3) THIS BUILDING (FOOTING) ALSO DOES NOT INDICATE TYPE
 OF OCCUPANCY AND MINIMUM BUILDING TYPE. 2007/09 FBC-B
 503. THIS INFORMATION IS REQUIRED TO VERIFY THE TYPE
 AND SIZE OF BUILDING IS DESIGN PER TABLE 503.
  
 4) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved