Date |
Text |
2011-08-05 16:08:52 | NEW SINGLE FAMILY (R3) CONSTRUCTION ROOF COVERING |
| BUILDING REVIEW CHECKLIST. |
| 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. |
| |
| 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| DCA RULE 9N-3 FOR THE PEEL & STICK UNDERLAYMENT TYPE TO |
| BE USED FOR WOOD SHAKES AND METAL ROOF APPLICATIONS AS |
| SPECIFIED BY THE ARCHITECT OF RECORD ON THE |
| CONSTRUCTION PLANS |
| |
| 2- COPPER ROOF SYSTEM W-18 ON FLORIDA PRODUCT APPROVAL |
| FL10601-R2 SUBMITTED DOESN'T MEET THE DESIGN PRESSURES |
| FOR THE ROOF CORNER AND PERIMETER AREAS. NEED TO |
| PROVIDE PRODUCT APPROVAL THAT MEETS THE DESIGN |
| PRESSURES AS REQUIRED BY SEC. R301.2.1.4.3. |
| |
| 3- BALCONY WATERPROOF SYSTEM PRODUCT APPROVAL |
| SUBMITTED: |
| A) CLEARLY MARK WHICH APPROVED ASSEMBLY FROM NOA |
| 10-0608.02 SUBMITTED IS GOING TO BE USED TO VERIFY |
| COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. |
| R301.2.1.4.3. |
| |
| B) PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR |
| NAIL ENHANCING AT PERIMETER AND CORNER AS REQUIRED BY |
| GENERAL LIMITATION #7 ON LAST PAGE OF NOA SUBMITTED. |
| |
| 4- ARCHITECT OF RECORD FOR THE NEW HOUSE TO REVIEW AND |
| APPROVE IN WRITING (NOT SIGNING & SEALING) ALL PRODUCT |
| APPROVALS PRIOR TO SUBMITTAL AS REQUIRED BY SEC. |
| 106.3.3 CITY AMENDMENTS TO FBC. |
| |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561)805-6712 |