Plan Review Notes
Plan Review Notes For Permit 11070719
Permit Number 11070719
Review Stop B
Sequence Number 1
Notes
Date Text
2011-08-03 16:05:31****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. SEE OPENING 2, BOTTOM. TAPCON NOT ALLOWED FOR
 SECTION 6 BOTTOM INTO MASONRY, SEE SHEET 10 OF PRODUCT
 APPROVAL.
  
 2. SEE SHEET 10 OF PRODUCT APPROVAL. AN EDGE DISTANCE
 OF 3" REQUIRES A .35 FACTOR FOR TAPCONS, .75 FOR SOLID
 SET. THIS FACTOR IS TO BE APPLIED TO THE ANCHOR SPACING
 IN THE ANCHOR SPACING SCHEDULE.
  
 FOR THIS PERMIT ONLY, PER CONVERSATION WITH OWNER,
 CONTRACTOR CAN RESUBMIT REVISED INSTALLATION SCHEDULE
 VIA EMAIL
  