2012-05-30 13:58:47PLANS ARE APPROVED WITH PROVISOS (RESPOND TO ALL
 COMMENTS IN WRITING IN ACKNOWLEDGEMENT)
  
 #1 RIGHT TURN ONLY EXIT CONCRETE APRON UNTO CONGRESS
 AVE NEEDS TO BE REVISED AND NARROWED TO AVOID CARS
 ENTERING SITE WHILE OTHERS ARE TRYING TO EXIT.
 (CONGRESS AVENUE IS A PALM BEACH COUNTY ROADWAY
 THEREFORE CONSULT WITH PBC ROAD ROW PERMIT WILL BE
 REQUIRED)
  
 #2 PROVIDE DETAILS AND/OR DESIGN SUMMARY FOR PROPOSED
 A.D.A. RAMP. (PLANS SUBMITTED DO NOT SHOW SLOPE,
 SPECIFIC DIMENSIONS (LENGTH, WIDTH, ETC.) AND DETAILS
 FOR A.D.A. HANDRAIL. (RAMP DETAILS MAY BE OBTAINED THRU
 WWW.ADA.ORG WEB SITE UNDER U.S. DEPARTMENT OF JUSTICE -
 ADA STANDARDS FOR ACCESSIBLE DESIGN. IF PERMIT FOR THIS
 ELEMENT HAS BEEN ISSUED UNDER ARCHITECTURE PLANS OR
 OTHER SOURCE PLEASE PROVIDE PERMIT NUMBER AND/OR
 INFORMATION.
  
 #3 PLAN IDENTIFIES TWO DUMPSTER AREAS; HOWEVER THESE
 AREAS ARE NOT LOCATED IN THE SAME VICINITY. PLEASE
 SPECIFY WHICH DUMPSTER WILL BE THE PRIMARY DUMPSTER FOR
 CITY OF WEST PALM BEACH SANITATION PICK-UP.
  
 #4 PLEASE VERIFY THAT THE 2" DOMESTIC METER (LOCATION:
 CONGRESS SIDEWALK 10 NORTH OF SOUTH DRIVE) HAS THE
 PROPER BACKFLOW PREVENTION DEVICE. INACTIVE 1" SERVICE
 (LOCATION: SIDEWALK 4' WEST OF OKEECHOBEE DRIVEWAY)
 COULD BE ACTIVATED AND DESIGNATED AS IRRIGATION. WITH
 CURRENT CONFIGURATION DOMESTIC WATER USED FOR
 IRRIGATION WILL BE CHARGED SEWAGE AGAINST IT.
  
 #5 ACCESS DRIVE EXITING TO 20FT WIDE ALLEY MUST BE AS
 PER CITY OF WEST PALM BEACH STANDARD DRIVEWAY APRON.
 20FT WIDE IS THE MAX + 3' FOOT FLARE + 3' CURB
 TRANSITION. APRON MUST BE 6" THICK CONCRETE AND 3000PSI
 MINIMUM. REFER TO:
 HTTP://WWW.WPB.ORG/ENGINEERING/PDF/STANDARDS/GC-6.PDF
  
 #6 IT IS HIGHLY SUGGESTIVE THAT CHAIN LINK FENCE
 SURROUNDING REAR LOT, BE PLACED AROUND DRY DETENTION
 AREAS. THIS WOULD ALLOW PROTECTION FOR PEDESTRIANS WHO
 COULD INADVERTENTLY WALK INTO THE SITE AND FALL.
  
 PLEASE FEEL FREE TO DIRECT ANY SPECIFIC QUESTION SHOULD
 YOU NEED CLARIFICATION ON ANY OF THE ABOVE MENTIONED
 ITEMS.
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved