Plan Review Notes
Plan Review Notes For Permit 11070617
Permit Number 11070617
Review Stop B
Sequence Number 2
Notes
Date Text
2011-10-05 11:20:59BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 BUILDING PLAN REVIEW
 PERMIT: 11070617
 ADD: 2301 OKEECHOBEE BLVD, BLDG# 1
 CONT: NORTH AMERICAN AUTOMOTIVE SERVICES
 TEL: (630)352-8126
  
 1A) PARTS MEZZANINE IS TO BE A PRE-ENGINEERED SYSTEM
 VENDOR INSTALLED, UNDER A SEPARATE PERMIT, REVIEW AND
 ASSOCIATED FEES.
  
 1B) 110.4.2 STORAGE & FACTORY- INDUSTRIAL OCCUPANCIES.
 IT SHALL BE THE RESPONSIBILITY OF THE OWNER, AGENT,
 PROPRIETOR OR OCCUPANT OF GROUP S AND GROUP F
 OCCUPANCIES, OR ANY OCCUPANCY WHERE EXCESSIVE FLOOR
 LOADING IS LIKELY TO OCCUR, TO EMPLOY A COMPETENT
 ARCHITECT OR ENGINEER IN COMPUTING THE SAFE FLOOR LOAD
 CAPACITY. ALL SUCH COMPUTATIONS SHALL BE ACCOMPANIED BY
 AN AFFIDAVIT FROM THE ARCHITECT OR ENGINEER STATING THE
 SAFE ALLOWABLE FLOOR LOADS ON EACH FLOOR IN POUNDS PER
 SQ FT. THE
 COMPUTATIONS & AFFIDAVIT SHALL BE FILED AS A PERMANENT
 RECORD OF THE BLDG DEPT.
  
  
 1C) 110.4.3.SIGNS REQUIRED. IN EVERY BUILDING OR PART
 OF A BUILDING USED FOR STORAGE, INDUSTRIAL OR HAZARDOUS
 PURPOSES, THE SAFE FLOOR LOADS, AS REVIEWED BY THE
 BUILDING OFFICIAL ON THE PLAN, SHALL BE MARKED ON
 PLATES OF APPROVED DE SIGN WHICH SHALL BE SUPPLIED &
 SECURELY AFFIXED BY THE OWNER OF THE BUILDING IN A
 CONSPICUOUS PLACE IN EACH STORY TO WHICH THEY RELATE.
 SUCH PLATES SHALL NOT BE REMOVED OR DEFACED, & IF LOST,
 REMOVED THE OWNER OF THE BUILDING SHALL REPLACE THEM.
  
 2) ROOFING APPROVALS:
  
 NOA: 07-1018.10
 DURO-LAST SINGLE PLY PVC ROOFING SYSTEM OVER CONCRETE
 DECK,
 PAGE 5, DECK TYPE 31 CONCRETE DECK INSULATED -217.5
 LIMITATION # 9
  
 NOA 09-0219.09
 JOHN MANVILLE ROOF INSULATION BOARD
 ROOF ASSEMBLIES ARE APPROVED UNDER SPECIFIC ROOF
 COVER?S PRODUCT NOA.
  
 NOA 07-1018.14
 DURO-LAST SINGLE PLY PVC ROOFING SYSTEM OVER WOOD DECK
 THE INDIVIDUAL SUB-SYSTEMS ARE NOT IDENTIFIED, ROOFING
 CONTRACTOR WILL NEED TO
 IDENTIFY SUB-SYSTEM AND IF LIMITATION # 7 APPLIES THEN
 ENHANCED FASTENING IN ZONES
 2 & 3 WILL NEED TO BE CALCULATED AND PREPARED BY EITHER
 A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR
 REGISTERED ARCHITECT.
  
  
  