Plan Review Notes
Plan Review Notes For Permit 11070337
Permit Number 11070337
Review Stop B
Sequence Number 1
Notes
Date Text
2011-07-14 15:01:40RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY FROM NOA
 09-0820.11 IS GOING TO BE INSTALLED TO VERIFY
 COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. R301.
  
 2- PROVIDE RAS 117 CALCULATIONS FOR INSULATION
 ATTACHMENT AS REQUIRED BY THE SELECTED APPROVED
 ASSEMBLY. AND BY GENERAL LIMITATION #7 FOR NAIL
 ENHANCING AT PERIMETER AND CORNER AREAS.
  
 ***NOTE: DESIGN PROFESSIONAL DOING THE CALCULATIONS TO
 TAKE INTO CONSIDERATION THAT ACCORDING TO SEC.
 R301.2.1.4.3 THIS BUILDING IS LOCATED ON EXPOSURE "C".
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712