Plan Review Notes
Plan Review Notes For Permit 11070120
Permit Number 11070120
Review Stop B
Sequence Number 1
Notes
Date Text
2011-07-19 13:47:22BUILDING PLAN REVIEW
 PERMIT: 11070120
 ADD: 225 DYER RD #2
 CONT: PALM BEACH WINDOW & DOOR
 TEL: (561)373-3902
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL .
  
 1) THE THREE PICTURES SUBMITTED AS REFERENCE TO SCOPE
 OF WORK DOES NOT MATCH UP WITH THE FLOOR PLAN OF
 WINDOWS TO BE REPLACED. AN EXAMPLE THE 2ND FLOOR FLOOR
 PLAN INDICATES TWO SEPERATE WINDOWS WITH A WALL SECTION
 BETWEEN THEM WHEREAS THE PICTURE OF THE SECOND FLOOR
 INDICATES TWO DOUBLE HUNG WINDOWS WITH COUNTER BALANCE
 SASH COMPARTMENT, THERE IS USUALLY NO FRAMING MEMBERS
 BETWEEN THE TWO WINDOWS.
  
 2.1) THE SECOND ISSUE IS THE PRODUCT APPROVAL SUBMITTED
 DOES NOT INDICATE ANY VERTICAL MULLIONS INCLUDED WITHIN
 THE PRODUCT APPROVAL. A SEPERATE MULLION REPORT WILL BE
 REQUIRED. 2007/09 FBC-B 1714.5.5
  
 2.2 PLEASE CIRCLE IN THE PRODUCT APPROVAL THE TYPE OF
 FASTENER TO BE USED FOR ANCHORING THESE WINDOWS AND
 TYPE OF MATERIAL THE WINDOWS WILL BE ANCHORED TO. IS
 THIS A WOOD FRAME/ STUCCO BUILDING?
  
 3) THE FIRST FLOOR FLOOR PLAN APPEARS TO HAVE SIMILAR
 ISSUES THE WINDOWS ARE DRAWN IN AS TWO INDIVIDUAL
 WINDOWS WITH WALL SEECTION BETWEEN THEM AND THE FIRST
 FLOOR PICTURE INDICATES THE SAME TWO DOUBLE HUNG WOOD
 SASH WINDOWS WITH COUNTER BALANCE COMPARTMENT BETWEEN
 THEM AND NO MULLION REPORT.
 THE QUESTION IS ARE THERE ONLY TWO WINDOWS ON THE FIRST
 FLOOR THIS ELEVATION OR IS THERE TWO PAIR OF WINDOW ?
  
 4) CONTRACTOR TO TAKE RESPONSIBILITY FOR PLANS
 SUBMITTED, AS THE DESIGNER OF RECORD, PLEASE PRINT
 NAME, SIGN YOUR NAME AND LICESNE NUMBER.
  
 5) PLANS ARE MISSING WIND DESIGN CRITERIA:
 1609.6.2 WIND DESIGN PROCEDURES
 4.1) THE BASIC WIND SPEED, V, SHALL BE DETERMINED IN
 ACCORDANCE WITH SECTION 1609.3. THE WIND SHALL BE
 ASSUMED TO COME FROM ANY HORIZONTAL DIRECTION.
  
 4.2) AN IMPORTANCE FACTOR, IW, SHALL BE DETERMINED IN
 ACCORDANCE WITH SECTION1609.5.
  
 4.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4.
  
 4.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.6.2.1(4)
  
 4.5 POSSITE & NEGATIVE PRESSURES
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  