2011-07-19 13:47:22 | BUILDING PLAN REVIEW |
| PERMIT: 11070120 |
| ADD: 225 DYER RD #2 |
| CONT: PALM BEACH WINDOW & DOOR |
| TEL: (561)373-3902 |
| |
| 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 2007 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| ACTION: DENIED |
| |
| 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK |
| PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, |
| RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| OFFICIAL . |
| |
| 1) THE THREE PICTURES SUBMITTED AS REFERENCE TO SCOPE |
| OF WORK DOES NOT MATCH UP WITH THE FLOOR PLAN OF |
| WINDOWS TO BE REPLACED. AN EXAMPLE THE 2ND FLOOR FLOOR |
| PLAN INDICATES TWO SEPERATE WINDOWS WITH A WALL SECTION |
| BETWEEN THEM WHEREAS THE PICTURE OF THE SECOND FLOOR |
| INDICATES TWO DOUBLE HUNG WINDOWS WITH COUNTER BALANCE |
| SASH COMPARTMENT, THERE IS USUALLY NO FRAMING MEMBERS |
| BETWEEN THE TWO WINDOWS. |
| |
| 2.1) THE SECOND ISSUE IS THE PRODUCT APPROVAL SUBMITTED |
| DOES NOT INDICATE ANY VERTICAL MULLIONS INCLUDED WITHIN |
| THE PRODUCT APPROVAL. A SEPERATE MULLION REPORT WILL BE |
| REQUIRED. 2007/09 FBC-B 1714.5.5 |
| |
| 2.2 PLEASE CIRCLE IN THE PRODUCT APPROVAL THE TYPE OF |
| FASTENER TO BE USED FOR ANCHORING THESE WINDOWS AND |
| TYPE OF MATERIAL THE WINDOWS WILL BE ANCHORED TO. IS |
| THIS A WOOD FRAME/ STUCCO BUILDING? |
| |
| 3) THE FIRST FLOOR FLOOR PLAN APPEARS TO HAVE SIMILAR |
| ISSUES THE WINDOWS ARE DRAWN IN AS TWO INDIVIDUAL |
| WINDOWS WITH WALL SEECTION BETWEEN THEM AND THE FIRST |
| FLOOR PICTURE INDICATES THE SAME TWO DOUBLE HUNG WOOD |
| SASH WINDOWS WITH COUNTER BALANCE COMPARTMENT BETWEEN |
| THEM AND NO MULLION REPORT. |
| THE QUESTION IS ARE THERE ONLY TWO WINDOWS ON THE FIRST |
| FLOOR THIS ELEVATION OR IS THERE TWO PAIR OF WINDOW ? |
| |
| 4) CONTRACTOR TO TAKE RESPONSIBILITY FOR PLANS |
| SUBMITTED, AS THE DESIGNER OF RECORD, PLEASE PRINT |
| NAME, SIGN YOUR NAME AND LICESNE NUMBER. |
| |
| 5) PLANS ARE MISSING WIND DESIGN CRITERIA: |
| 1609.6.2 WIND DESIGN PROCEDURES |
| 4.1) THE BASIC WIND SPEED, V, SHALL BE DETERMINED IN |
| ACCORDANCE WITH SECTION 1609.3. THE WIND SHALL BE |
| ASSUMED TO COME FROM ANY HORIZONTAL DIRECTION. |
| |
| 4.2) AN IMPORTANCE FACTOR, IW, SHALL BE DETERMINED IN |
| ACCORDANCE WITH SECTION1609.5. |
| |
| 4.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN |
| ACCORDANCE WITH 1609.4. |
| |
| 4.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * |
| SHALL BE DETERMINED FROM TABLE 1609.6.2.1(4) |
| |
| 4.5 POSSITE & NEGATIVE PRESSURES |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| CONSTRUCTION SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |