2011-10-01 10:52:54AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 THE HANDICAP PARKING SPACES REQUIRE A FIVE-FOOT (5)
 QUEUING SPACE ADJACENT TO THE STALL. THE DRAWING
 INDICATE THE THIS SPACE HAS BEEN ELIMINATED FOR FOUR
 (4) STALLS. PARKING SPACES FOR THE DISABLED MUST BE
 POSTED. THE DRAWINGS DO NOT SHOW THE LOCATIONS OF THE
 SIGN POSTS AS REQUIRED.
  
 THE ANGLE OF THE PARKING SPACES MUST BE INDICATED ON
 THE DRAWINGS.
  
 THE DIMENSIONS OF THE STALLS MUST BE INDICATED ON THE
 DRAWINGS.
  
 TERMINAL AREAS AT THE END OF THE PARKING ROWS MUST
 SHOWN ON THE DRAWINGS.
  
 THE PARKING STALLS ALONG THE EASTERN EDGE OF THE SITE
 ENCROACH ON THE ADJACENT PROPERTY. PLEASE REVISE THE
 DRAWINGS AND LOCATE ALL PARKING STALLS ON THE SUBJECT
 PROPERTY.
  
 THE WIDTH OF THE DRIVE AISLE ADJACENT TO THE SIGN IS
 INSUFFICIENT FOR TRAVEL. THE MINIMUM WIDTH REQUIRED FOR
 ONE-WAY TRAVEL IS 12 FEET.
  
 PLEASE AFIX THE CITY'S STANDARD PARKING DETAIL TO THE
 DRAWINGS.