2011-07-15 11:52:022007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) DUE TO THE PROXIMITY OF THE PROPOSED POOL TO THE
 EXISTING DWELLING, IT WILL BE NECESSARY TO PROVIDE
 SHORING TO PROTECT THE EXISTING FOUNDATION DURING
 CONSTRUCTION. SUBMIT TWO COPIES OF A SHORING PLAN FROM
 FLORIDA LICENSED ENGINEER. FBC 3304.1 AND FBC R
 403.1.7.2
  
 2) SOME OF THE BEARING LOADS OF THE DWELLING FOOTINGS
 MAY BE TRANSFERED AS LATERAL LOADS TO THE POOL WALLS.
 THIS SHOULD BE CONSIDERED IN THE POOL DESIGN. FBC
 R301.1
  