Plan Review Notes For Permit 11060128 |
Permit Number |
11060128 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2011-06-09 09:10:24 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. TWO COMPLETE SETS OF DOCUMENTS ARE REQUIRED FOR | | PERMIT ISSUANCE. FAILURE TO PROVIDE TWO SETS OF THE | | INSTALLATION SCHEDULE MAY RESULT IN PERMIT ISSUANCE | | DELAYS. | | | | 2. SPANS ARE NOT CORRECT. FOR INSTANCE, SEE OPENING 1. | | OPENING IS W X H, VERTICAL INSTALLATION, SO SPAN SHOULD | | CORRELATE WITH OPENING HEIGHT, NOT WIDTH. | | | | 3. 9" ANCHOR SPACING PROPOSED FOR BOTTOM CONNECTION | | DOES NOT COMPLY WITH THE CHART ON SHEET 10 OF THE | | PRODUCT APPROVAL. PLEASE REVISE. | | | | | | |
|