Plan Review Notes
Plan Review Notes For Permit 11050538
Permit Number 11050538
Review Stop B
Sequence Number 1
Notes
Date Text
2011-05-31 13:33:552007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO SETS OF STRUCTURAL DRAWINGS SHOWING THE
 MATERIALS AND METHOD THAT WILL BE USED TO REDUCE THE
 EXISTING DOOR OPENING IN SIZE. PROVIDE OPENING
 DIMENSIONS AND DOOR SIZE ON THE DRAWINGS. SPECIFY THE
 STRUCTURAL WIND DESIGN DATA ON THE DRAWINGS. THE
 WINDSPEED, EXPOSURE CATEGORY, MEAN ROOF HEIGHT,
 COMPONENT AND CLADDING PRESSURES. FBC 1603.1.4 AND CITY
 AMENDMENTS 106.1.2
  
 2) INDICATE IF THIS NEW SMALLER DOOR IS A REQUIRED
 MEANS OF EGRESS. SPECIFY THE TYPE OF OCCUPANCY,
 OCCUPANT LOAD, REQUIRED NUMBER OF EXITS AND MINIMUM
 EGRESS WIDTH AND EGRESS DOOR WIDTHS. SEE 2007 FBC
 CHAPTER 10 "MEANS OF EGRESS".
  
 3) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE
 NEW SMALLER FRONT DOOR AS REQUIRED BY DCA RULE 9B-72.
  
 4) SUBMIT TWO COPIES OF AN ELEVATION DRAWING SHOWING
 THE DIMENSIONS OF THE AREA THAT WILL BE STUCCOED. CITY
 AMENDMENTS 106.1.2
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]