Notes |
Date |
Text |
2011-06-02 13:36:08 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. REVISE PLAN TO SHOW DISTANCE FROM GRADE TO BOTTOM OF | | AWNING, FBC3202. | | | | 2. PLEASE PROVIDE CLARIFICATION, IT IS NOT CLEAR HOW | | THE RAISED PARAPET WILL RESIST WIND LOADS FBC1609. IT | | APPEARS THAT THIS ACTS AS A VERTICAL CANTALEVER, BUT NO | | SUPPORTS TO PROVIDE STRUCTURAL CONTINUITY TO THE | | EXISTING STRUCTURE PROVIDED. PLEASE PROVIDE INFORMATION | | (CALCULATIONS, RATIONALE, ETC.) TO DEMONSTRATE THAT THE | | FASTENERS PROPOSED WILL BE ADEQUATE TO PREVENT THE | | RAISED PARAPET FROM FOLDING WHEN SUBJECTED TO WIND | | LOADS (BOTH DIRECTIONS). PLEASE CONTACT ME IF THE | | COMMENT DOES NOT CLEARLY EXPRESS CONCERNS. | | | | 3. INFORMATIONAL ONLY, AWNING ENGINEERING TO BE | | PROVIDED AT INSPECTION. | | | | 4. INFORMATIONAL ONLY, PLAN SHOWS PROPOSED ELECTRIC BUT | | NO ELECTRIC PLAN PROVIDED. ELECTRIC PLANS WILL BE | | REQUIRED WITH ELECTRIC PERMIT APPLICATION. | | |
|