2011-05-17 20:06:28 | PLANNING AND ZONING: **** FAILED **** |
| |
| |
| 1. RESPOND TO COMMENTS IN WRITING. |
| |
| 2. 2. PROVIDE DIMENSIONS TO ALL PROPERTY LINES OF POOL |
| (EQUIPMENT) ON BOTH THE SURVEY/SITE PLAN. PURSUANT TO |
| SECTION 94-305(B)(4) OF THE ZLDR: MECHANICAL EQUIPMENT |
| MAY NOT PROJECT MORE THAN 4 FEET INTO A REQUIRED |
| SETBACK. |
| |
| 3. AS THE SURVEY DOES NOT SHOW AN EXISTING PERMANENT |
| FENCE COMPLETELY SURROUNDING THE POOL, A FENCE PERMIT |
| SHALL BE SUBMITTED CONCURRENTLY AND SHALL CONFORM TO |
| THE MINIMUM STANDARDS PROVIDED BELOW: |
| |
| PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND |
| DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B) AND |
| (C): |
| B. EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE OR |
| SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS |
| BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE |
| RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. |
| BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN |
| HEIGHT ABOVE GRADE. |
| C. ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH |
| A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING |
| GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES |
| PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE. AT |
| LEAST 90 PERCENT OF THE SURFACE AREA OF ALL SCREEN |
| ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH WHICH |
| AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT SHALL |
| BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A |
| 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, |
| AT THE PROPERTY LINE, TO ENSURE PRIVACY. |
| |
| REFERENCE THE POOL PERMIT NUMBER WHEN SUBMITTING THE |
| FENCE PERMIT AND VICE VERSA. |
| |
| IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. |
| |
| LINDA MIA FRANCO |
| SENIOR PLANNER |
| PLANNING AND ZONING DEPARTMENT |
| TEL: (561) 822-1443 |
| EMAIL: [email protected] |
| |