2011-05-26 11:30:12RESIDENTIAL (R3) ADDITION, BUILDING REVIEW CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- ENGINEER OF RECORD NEEDS TO UPDATE HIS LICENSE WITH
 THE FLORIDA DEPARTMENT OF BUSINESS & PROFESSIONAL
 REGULATION (DBPR). HIS STATUS IS DELINQUENT. ENGINEER
 TO CONTACT THE DBPR TO UPDATE HIS LICENSE STATUS.
  
 2- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD.) TO VERIFY IF IMPACT FEES ARE
 DUE. BRING BACK STAMPED PLANS AND COPY OF PAID RECEIPT
 IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF THE
 UNIFIED LAND DEVELOPMENT CODE.
  
 3- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTE.
 ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK
 UP.
  
 4- ENGINEER TO REVISE THE BUILDING EXPOSURE. ACCORDING
 TO 2009 REVISIONS SEC. R301.2.1.4.3 THIS BUILDING IS
 LOCATED ON EXPOSURE "C" NO "B". REVISE BUILDING
 EXPOSURE AND ALL DESIGN PRESSURES ACCORDINGLY. REVISE
 DESIGN CRITERIA ON SHEET #2 AND SHEET # T-1.
  
 5- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 A) SINGLE HUNG WINDOWS. 2 DIFFERENT PRODUCT APPROVALS
 WERE SUBMITTED. FLORIDA PRODUCT APPROVAL FL239-R12
 SUBMITTED FOR PGT WINDOWS IS MISSING THE DRAWINGS
 SHOWING THE WINDOWS SPECS. IN ADDITION NOA 09-0316.10
 SUBMITTED FOR AWP WINDOWS IS SUPERSEDED BY MIAMI-DADE.
 VISIT MIAMI-DADE WEBSITE AND DOWNLOAD CURRENT NOA.
 PLEASE SELECT ONLY ONE WINDOW COMPANY AND CORRESPONDING
 PRODUCT APPROVAL.
  
 B) SHINGLES NOA 08-1110.11 SUBMITTED WAS SUPERSEDED BY
 MIAMI-DADE. VISIT MIAMI-DADE WEBSITE AND DOWNLOAD
 CURRENT NOA. NOTE: DOWNLOAD CURRENT NOA 10-11222.08.
  
 C) STORM PANELS. FLORIDA PRODUCT APPROVAL FL7030
 SUBMITTED IS FOR 2004 CODE. NEED TO PROVIDE PRODUCT
 APPROVAL FOR 2007 CODE VERSION.
 ****ALSO: PROVIDE SHUTTERS COMPLETE INSTALLATION
 SCHEDULE. AND, CLEARLY MARK ON SHUTTERS DRAWINGS
 SPECIFIC SHUTTERS MOUNTING CONDITIONS AND ANCHOR TYPE
 AND SPACING TO BE USED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.
  
 D) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND DETAILS. NOTE: PROVIDE ONLY THE PRODUCT APPROVAL
 COVER PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR.
 OR, ENGINEER TO SPECIFY STRUCTURAL CONNECTOR PRODUCT
 APPROVAL NUMBER ON DRAWINGS.
  
 E) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 6- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC.
  
 7- SHEET T-1: ENGINEER TO REVISE ROOF SHEATHING NAILING
 NOTE. NEED TO SPECIFY 8D RING SHANK NAILS AT 4"O.C. IN
 ROOF ZONE #3 AS REQUIRED BY SEC. R803.2.3.1. ALSO, ROOF
 PERIMETER AND CORNER AREAS NEED TO BE SPECIFIED AS
 4'-0" MIN. SEE FIGURE R301.2(7).
  
 8- SURVEY SUBMITTED: A) PROPERTY IS LOCATED ON FLOOD
 ZONE "B" NO "C". REVISE AS REQUIRED.
  
 B) SURVEY TO HAVE ORIGINAL SIGNATURE AS REQUIRED BY
 CHAPER 472 FLORIDA STATUTE WHEN SUBMITTING SURVEYS FOR
 PUBLIC RECORDS.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712
  
  