Notes |
Date |
Text |
2011-04-21 15:21:46 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. SEE SHEET 10 OF PRODUCT APPROVAL. THE ANCHOR SPACING | | FOR CONCRETE SUBSTRATE HAS BEEN USED, BUT THE SUBSTRATE | | SPECIFIED IN INSTALLATION SCHEDULE IS CONCRETE BLOCK. | | NOTE THAT THE INSTALLATION MAY NOT BE PERMITTED FOR | | THIS SUBSTRATE AND THE ANCHOR SELECTED, SEE "NA" ON THE | | ANCHOR CHARTS. REVISE THE INSTALLATION SCHEDULE TO | | COMPLY WITH REQUIRMENTS OF THE PRODUCT APPROVAL. | | | | 2. SHOW THE EMERGENCY MEANS OF ESCAPE, FBC R310.4. | | | | | | |
|