2011-05-09 17:16:23 | FAILED: |
| YOUR PAVING AND DRAINGE PLAN IS DEFFICIENT AND A |
| SEPARATE SUBMITTAL WILL NEED TO BE MADE DIRECTLY TO |
| ENGINEERING SERVICES DEPARTMENT. |
| GO TO |
| HTTP://WWW.CITYOFWPB.COM/ENGINEERING/ENG_FORMS.PHP |
| GO TO |
| HTTP://WWW.CITYOFWPB.COM/ENGINEERING/UPLOADS/2010-10-20 |
| -16-37-34-DEVELOPMENTPERMITPACKAGE2011.PDF |
| PRINT AND SUBMIT: |
| #1 DEVELOPMENT APPLICATION COVER |
| #2 STANDARD APPLICATION FOR DEVELOPMENT PERMIT FORM |
| ALONG WITH |
| 1. ENGINEERING PLANS - SIX (6) SETS OF SIGNED AND |
| SEALED PLANS IN THE ORDER LISTED BELOW, ALONG WITH A |
| LETTER DESCRIBING THE SUBMITTAL. |
| A. COVER SHEET |
| B. PAVING, GRADING, AND DRAINAGE PLANS |
| C. PAVING, GRADING, AND DRAINAGE DETAILS |
| F. OFFSITE IMPROVEMENTS (DRIVEWAY APRONS, SIDEWALKS, |
| SERVICE RELOCATION/MODIFICATIONS, ETC) |
| G. STORMWATER POLLUTION PROTECTION PLAN |
| 2. DRAINAGE CALCULATIONS - 2 COPIES SIGNED AND SEALED |
| (INCLUDE SURFACE WATER MANAGEMENT CALCULATIONS IN ACRES |
| AND S.F.) |
| A.IDENTIFY LOCATION ON OUTFALL OR CITY CONNECTION. IF |
| NOT IN USE CITY WILL HAVE DEVELOPER/OWNER CAP AND |
| ELIMINATE SUCH SERVICE. |
| 3. ENGINEER'S COST ESTIMATE. |
| |
| TO: ENGINEERING SERVICES DEPARTMENT |
| ATTENTION: MR. BRIAN MOREE, |
| 401 CLEMATIS STREET, 4TH FLOOR |
| WEST PALM BEACH, FL 33401 |
| (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) |
| |
| SITE SPECIFIC COMMENTS: |
| |
| #1 EXISTING DRAINAGE WILL CONFLICT WITH NEW FOUNDATION. |
| COMPARE C-1 AND S-3. |
| |
| #2 SITE DESIGN MUST RETAIN 1ST INCH OF RAINFALL BEFORE |
| DISCHARGE AT A CONTROL ELEVATION. |
| |
| #3 SITE DOMESTIC WATER METER WILL REQUIRE A BACKFLOW. |
| SITE POSES A CHALLENGE AS THE DOMESTIC METER GOES |
| DIRECTLY INTO NORTH BUILDING WALL WITH NO GREEN AREA. A |
| NEW TAP LOCATED WHERE BACKFLOW WILL BE JUST INSIDE THE |
| PROPERTY FOLLOWING THE CITY METER MAY BE NEEDED. |
| |
| #4 SITE PAVING AND DRAINAGE DESIGN WILL NEED SPOT |
| ELEVATION OF EXISTING AND PROPOSED SO THAT WATER IS |
| RETAINED ON-SITE PRIOR TO DISCHARGE. |
| |
| #5 ANY PROPOSED STRUCTURE OR CATCH BASIN TOP MUST BE |
| SHOWN IN DETAIL. |
| |
| #6 EXISTING 8" CAST IRON PIPE WILL BE ALLOWED IF |
| CLEAN-OUTS AREA PROVIDED AT BENDS AND IF RE-ROUTED FROM |
| UNDER THE BUILDING. |
| |
| #7 PROVIDE SIGNED AND SEALED DRAINAGE CALCULATIONS |
| SUMMARY. |
| |
| #8 C-1 TRENCH DRAIN SHOWN ON SHEET C-1 CAN BE REMOVED |
| IF LOCATED ON PRIVATE PROPERTY; OTHERWISE YOU WILL NEED |
| AN FDOT UTILITY PERMIT TO REMOVE AND/OR MODIFY. |
| |
| #9 FLOOR PLAN PLUMBING PLAN P-1 SHOWS THE SEWER COMING |
| OUT THE NORTH WALL, ASBUILTS IN OUR OFFICE REFLECT A |
| SEWER LATERAL OFF S DIXIE HWY. (FIELD VERIFY). |
| |
| #10 SHOW CONNECTION OF ROOF DRAIN INTO STORM. ON THE |
| PLANS IT DOES NOT CONNECT TO ANYTHING. |
| |
| # 11 PARKING LOT LAY-OUT DESIGN SHALL BE IN ACCORDANCE |
| WITH THE ZONING ORDINANCE. PARKING STALLS AND AISLE |
| DIMENSIONS MUST BE SHOWN ON DEVELOPMENT PLANS. ALL |
| PARKING LOTS REGARDLESS OF SIZE SHALL PROVIDE FOR |
| PROPER DRAINAGE. THE MINIMUM LONGITUDINAL GRADIENT |
| (SLOPE) SHALL BE 0.4 PER CENT IN BOTH DIRECTIONS. ALL |
| RUNOFF SHALL BE COLLECTED ON SITE, FOR PROVISIONS OF |
| WATER QUALITY AND QUANTITY CONTROL, PRIOR TO DISCHARGE |
| TO THE CITY'S DRAINAGE FACILITIES. |
| |
| # 12 WATER QUALITY RETENTION VOLUME CALCULATION: |
| RETENTION OF THE 1ST INCH OVER THE PROJECT AREA OR 2.5 |
| TIMES THE PERCENTAGE OF IMPERVIOUS AREA WILL NEED TO BE |
| DOCUMENTED FOR WATER QUALITY PURPOSES. |
| |
| # 13 REVISE SHEET C-1 NOTES CALL OUT CITY OF MIAMI |
| BEACH PUBLIC WORKS (NOTE 10) AND IT REFERENCES CITY OF |
| WPB PUBLIC WORKS MANUAL. (NO SUCH THING) REFERE TO |
| ENGINEERING SERVICES DEPARTMENT STANDARDS. |
| |
| ******************************************************* |
| ********** |
| GENERAL COMMENTS: |
| EXISTING DEVELOPMENTS THAT PROPOSE ADDITIONAL |
| STRUCTURES AND/OR PARKING FACILITIES FOR APPROVAL MUST |
| PROVIDE STORMWATER MANAGEMENT AS REQUIRED ABOVE FOR THE |
| NEW FACILITIES ONLY. HOWEVER, IT WILL BE THE |
| RESPONSIBILITY AND A REQUIREMENT OF THE DEVELOPER'S |
| ENGINEER TO DETERMINE AND CERTIFY THAT PROPOSED AND |
| EXISTING FACILITIES TOGETHER WILL NOT ADVERSELY AFFECT |
| THE SITE DRAINAGE, STATE AND/OR FEDERAL REGULATIONS AS |
| A WHOLE OR THE EXISTING AND FUTURE WATER QUALITY |
| RESULTING FROM ANY INCREASES TO THE EXISTING IMPERVIOUS |
| AREAS OF THE SITE. |
| |
| EXISTING BUILDINGS WHICH HAVE PLUMBING DRAIN OUTLETS AT |
| AN ELEVATION 12? OR LESS ABOVE THE GROUND SURFACE OF |
| THE NEXT UPSTREAM MANHOLE, WHERE THE ELEVATION OF ANY |
| FLOOR IS AT OR BELOW THE INVERT OF THE ADJACENT CITY |
| SANITARY SEWER MAIN OR |
| IS LESS THAN 12?ABOVE THE GROUND SURFACE OF THE NEXT |
| UPSTREAM MANHOLE, OR WHERE A CONDITION EXISTS WHERE A |
| PLUG IN THE CITY SANITARY SEWER MAIN WILL CAUSE THE |
| HYDRAULIC GRADIENT TO RISE ABOVE THE LOWEST FLOOR |
| LEVEL. |
| |
| CITY ORDINANCE 3132-98, SECTION 32-18(A): "...IT SHALL |
| BE UNLAWFUL FOR ANY PERSON TO DIRECTLY OR INDIRECTLY |
| DEPOSIT, DISCHARGE, SPILL, OR DUMP INTO ANY OF THE |
| PUBLIC WATERS OR MUNICIPAL SEPARATE STORM SEWER SYSTEM |
| WITHIN THE CITY, ANY SUBSTANCE OTHER THAN THAT COMPOSED |
| ENTIRELY OF STORM WATER." AND, SECTION 32-18(C): "NO |
| PERSON MAY MAINTAIN, USE OR ESTABLISH ANY DIRECT OR |
| INDIRECT CONNECTION TO THE STORM WATER SYSTEM THAT |
| RESULTS IN ANY DISCHARGE IN VIOLATION OF THIS |
| ORDINANCE. THIS PROHIBITION IS RETROACTIVE AND APPLIES |
| TO CONNECTIONS MADE IN THE PAST, REGARDLESS OF WHETHER |
| MADE UNDER A PERMIT, OR OTHER AUTHORIZATION, OR WHETHER |
| PERMISSIBLE UNDER LAWS OR PRACTICES APPLICABLE OR |
| PREVAILING AT THE TIME THE CONNECTION WAS MADE." |
| |
| EXFILTRATION TRENCHES ARE DISCOURAGED BECAUSE THE |
| EXFILTRATION THAT THEY PROVIDE ARE FOUND TO DECREASE |
| WITH AGE, IF THEY ARE NOT PROPERLY MAINTAINED OR |
| REPLACED WHEN THEY DO NOT PROVIDE THE SERVICES INTENDED |
| BY THE DESIGN. HOWEVER, IF THE DEVELOPER'S ENGINEER, |
| DEVELOPER AND/OR OWNER DETERMINES THAT EXFILTRATION |
| TRENCHES ARE TO BE PROVIDED FOR WATER QUALITY OR |
| QUANTITY, THEIR DESIGN MUST CONFORM TO THE METHODOLOGY |
| OF SFWMD. SITE'S HYDRAULIC CONDUCTIVITY TEST REPORTS AT |
| THE LOCATION OF THE PROPOSED TRENCH SHALL BE SUBMITTED |
| TO THE CITY ENGINEER TOGETHER WITH THE CALCULATIONS; |
| SITE DEVELOPMENTS THAT USE EXFILTRATION TRENCHES FOR |
| BOTH, WATER QUALITY AND QUANTITY WITHOUT OVERFLOW |
| CAPABILITIES MUST PROVIDE ENOUGH TRENCH CAPACITY TO |
| HANDLE THE DIFFERENCE BETWEEN THE POST-DEVELOPMENT AND |
| PRE-DEVELOPMENT RUNOFF. |
| |
| CHAPTER 62.302, F.A.C. EFFECTIVELY STATES THAT THE SITE |
| IS NOT ALLOWED TO DISCHARGE ANY QUANTITY OF WATER THAT |
| VIOLATES STATE WATER QUALITY STANDARDS. CITY ORDINANCE |
| 3132-98, SECTION 32-18(A) STATES THAT IT IS A VIOLATION |
| TO DISCHARGE ANYTHING EXCEPT STORM WATER INTO THE |
| CITY'S MS4. THE CITY HAS THE AUTHORITY AND OBLIGATION |
| TO ENFORCE THESE RESTRICTIONS. IF THE APPLICANT'S |
| PROPOSED SYSTEM IS NOT PROVIDING SUFFICIENT WATER |
| QUALITY TREATMENT (SO THAT ANY DISCHARGE IS FREE OF ALL |
| BUT STORM WATER RUN-OFF), THEN APPLICANT MUST RE-DESIGN |
| THE SYSTEM. |
| |
| ******************************************************* |
| ********** |
| MANUEL JULIAN GONZALEZ |
| CONSTRUCTION SERVICE DEPARTMENT ENGINEERING REVIEW |
| ENGINEERING SERVICES DEPARTMENT |
| 401 CLEMATIS STREET, 4TH FLOOR |
| WEST PALM BEACH, FL 33401 |
| (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) |
| MAIN PHONE: (561) 822-1200 |
| DIRECT: (561) 494-1085 |
| FAX: (561) 494-1116 |
| MOBILE: (561) 644-7301 |
| EMAIL: [email protected] |
| WWW.WPB.ORG/ENGINEERING |
| |
| |
| |