Plan Review Notes For Permit 11040284 |
Permit Number |
11040284 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2011-05-10 11:26:10 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. SEE OPENING 4, BOTTOM CONNECTION TYPE "D", ANCHOR | | SPACING OF 7" CIRCLED ON PRODUCT APPROVAL IS IN THE | | SECOND COLUMN OF THE 8'0" ROW (PAGE 13). THE SECOND | | COLUMN REQUIRES USE OF ALL POINTS SOLID SET. TAPCONS | | CANNOT BE USED FOR THIS SPAN (SEE "-" IN THE TAPCON | | ROW, WHICH IS THE FIRST ROW OF THE 8'0" SECTION OF THE | | CHART). | | | | ALSO NOTE THAT D WALL SILL MOUNTED W/12 WAS CIRCLED, | | NOT ALLOWED FOR THIS CONNECTION TYPE, BUT IS ALLOWED | | FOR D WALL SILL MOUNTING W/14. PLANS WERE NOT REDLINED | | AS I DO NOT KNOW HOW THIS WILL AFFECT THE JOB OR IF | | THIS MOUNTING TYPE IS POSSIBLE FOR THIS APPLICATION. | | | | | | | | |
|