2011-04-19 14:23:03 | ****CORRECTIONS**** |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| FBC FLORIDA BUILDING CODE 2007 |
| FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL |
| |
| 1. VALUE IS TO INCLUDE LABOR AND MATERIALS. PROVIDE AN |
| INVOICE FROM STORM DEPOT TO PROVIDE EVIDENCE OF |
| MATERIAL COST. |
| |
| 2. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR |
| PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS |
| FS471. |
| |
| 3. PROVIDE INFORMATION TO SHOW HOW YOU HAVE DETERMINED |
| THAT THE SUBSTRATE ON THE BOTTOM IS CONCRETE. TYPICALLY |
| THE SUBSTRATE IS CONCRETE AT THE TOP, CONCRETE AT THE |
| BOTTOM. ALTERNATIVELY, REVISE BOTTOM SUBSTRATE TO |
| CONCRETE BLOCK AND REVISE ANCHOR SPACING ACCORDINGLY. |
| FBC R301. |
| |
| 4. PROVIDE INFORMATION REGARDING THE EMERGENCY MEANS OF |
| ESCAPE, FBC R310.4. SHOW ROOM DESIGNATIONS AND TYPE OF |
| OPENING. TWO OPENINGS ARE SHOWN ON THE FLOOR PLAN AS |
| "EXIT" BUT BOTH ARE TO BE COVERED WITH ACCORDION |
| SHUTTERS. IT IS NOT CLEAR HOW THE OPENINGS WILL COMPLY |
| WITH THE REQUIREMENTS OF THE CODE. |
| |
| 5. THE "SHUTTER CONNECTION MOUNTING TYPE" ON THE |
| INSTALLATION SCHEDULE IS TO CORRELATE WITH THE ANCHOR |
| CHART, SEE PAGE 6. BASED ON INFORMATION HIGHLIGHTED, IT |
| APPEARS THAT YOU PROPOSE TO USE MOUNTING TYPE "C2," SEE |
| PAGE 3 OF PRODUCT APPROVAL. PLEASE NOTE THAT |
| HIGHLIGHTED INFORMATION DOES NOT APPEAR WHEN SCANNED, |
| AND CANNOT BE USED TO SHOW CODE COMPLIANCE. PLEASE |
| REVISE THE INSTALLATION SCHEDULE TO INCLUDE REQUIRED |
| INFORMATION. |
| |
| 6. SHUTTER SPAN FOR AN ACCORDION SHUTTER IS THE BLADE |
| LENGTH. SEE OPENING 6, 268" IS STATED AS SPAN. THIS |
| EXCEEDS THE MAXIMUM PERMITTED BY THIS PRODUCT APPROVAL; |
| HOWEVER, IT APPEARS THAT YOU HAVE USED THE SHUTTER |
| WIDTH. PLEASE ADDRESS. |
| |
| |
| |