2011-03-22 16:15:13 | ****CORRECTIONS**** |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| FBC FLORIDA BUILDING CODE 2007 |
| FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL |
| |
| 1. CLARIFY SCOPE. APPLICATION IS FOR DOORS AND |
| SHUTTERS, PLAN SHOWS DUMPSTER ENCLOSURE AND CANOPY, AND |
| CANOPY PRODUCT APPROVAL WAS SUBMITTED. REMOVE |
| UNNECESSARY DETAILS FROM THE PLAN OR REVISE THE |
| APPLICATION. |
| |
| 2. DETAIL FOR "EXISTING STOREFRONT TO BE PROVIDED WITH |
| ACCORDION SHUTTERS" DOES NOT CORRELATE WITH THE SITE |
| PLAN. |
| |
| 3. PLAN SHOWS THAT A 4' DOOR WILL REPLACE A 3' EXISTING |
| DOOR, PROVIDE A STRUCTURAL DETAIL FOR THE ENLARGED |
| OPENING. |
| |
| 4. PROVIDE THE PRODUCT APPROVAL COVER SHEET FOR THE |
| ACCORDION SHUTTERS. |
| |
| 5. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE |
| ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER |
| FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. |
| THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET |
| AT |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ |
| INSTALLATION.PDF |
| |
| 6. PROVIDE A FLOOR PLAN SHOWING WHERE THE SHUTTERS WILL |
| BE INSTALLED AND PANEL SIZES WHICH CORRELATES WITH THE |
| INSTALLATION SCHEDULE, ITEM 5 ABOVE. FBC R301, FBC1609, |
| FBC*106. |
| |
| 7. IT APPEARS THAT THIS APPLICATION PROPOSES COVERING |
| EXIT DOORS WITH ACCORDION SHUTTERS. SEE FBC 1003.6, |
| MEANS OF EGRESS CONTINUITY. THE PATH OF EGRESS TRAVEL |
| ALONG A MEANS OF EGRESS SHALL NOT BE INTERRUPTED BY ANY |
| BUILDING ELEMENT OTHER THAN A MEANS OF EGRESS COMPONENT |
| AS SPECIFIED IN THIS CHAPTER. |
| |
| |
| |