Plan Review Notes
Plan Review Notes For Permit 11020301
Permit Number 11020301
Review Stop B
Sequence Number 1
Notes
Date Text
2011-02-28 09:57:462007 FBC W/2009
  
 DENIED BY BUILDING
  
 1) SUBMIT A COPY OF THE PAID RECEIPT FOR THE COUNTY
 IMPACT FEES.
  
 2) THE FLORIDA PRODUCT APPROVAL COVERSHEETS FOR THE
 WINDOWS, MULLIONS AND DOORS ARE FOR THE 2004 CODE
 VERSION. SUBMIT THE ONES FOR THE 2007 CODE VERSION.
  
 3) THE FLORIDA PRODUCT APPROVAL COVERSHEET FOR THE DOOR
 IS FROM A DIFFERENT MANUFACTURER (BENCHMARK) THAN THE
 ATTACHED MIAMI-DADE NOA (JELD-WEN). THE FILE STATUS IS
 CLOSED FOR THE NOA NO. 07-0731.04. SUBMIT CURRENT
 PRODUCT APPROVAL THAT HAS BEEN REVIEWED AND APPROVED BY
 THE DESIGNER OF RECORD.
  
 4) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE FIXED
 GLASS WINDOW IN THE NEW BEDROOM.
  
 5) THE ENERGY CALCULATION FORM THAT WAS SUBMITTED
 REQUIRES CEILINGS TO BE INSULATED TO A MINIMUM OF R-30.
 THE PLANS SPECIFY R-19 INSULATION IN THE CEILINGS AND
 THE FORM HAS R-19. IN ORDER TO USE THIS METHOD EACH
 COMPONENT IS REQUIRED TO MEET OR EXCEED THE PERFORMANCE
 CRITERIA ON THE FORM, OTHERWISE METHOD A MUST BE USED.
 PLEASE CORRECT.
  
 6) THE OWNER/AGENT IS REQUIRE TO SIGN THE ENERGY
 CALCULATION FORMS.
  
 7) SHOW COMPLIANCE WITH FBC R703.6.3 FOR THE REQUIRED
 BOND BREAK BETWEEN THE WATER-RESISTIVE BARRIER AND THE
 EXTERIOR STUCCO.
  
 8) SHOW COMPLIANCE WITH FBC R703.6.2 AND ASTM C 1063
 FOR THE FOUNDATION WEEP SCREED AT THE BOTTOM OF ALL
 FRAMED EXTERIOR WALLS BELOW THE FLOOR LINE WHERE THE
 WALL IS SUPPORTED BY A FLOOR OR FOUNDATION.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]