2011-03-01 09:23:31SUBMIT THE FOLLOWING:
  
 1. PLANS WATER, SEWER PAVING AND DRAINAGE.
  
 2. PAVING AND DRAINAGE PLAN SHOULD INCLUDE SURFACE
 WATER CALCULATIONS (PERVIOUS AND IMPERVIOUS AREAS)
  
 3. PLANS SHOULD SHOW H.C. DETAILS AND ADA ACCESSIBILITY
  
 4. CLUBHOUSE MUST HAVE PROPER BACKFLOW PREVENTION AT
 POINT OF SERVICE. SHOW LOCATION OF DOMESTIC METER
 (PRIVATE).
  
 5. SHOW LOCATION OF SEWER CLEAN-OUT AT POINT OF SEWER
 SERVICE (PRIVATE).
  
 6. SEPARATION BETWEEN WATER AND SEWER LINES NEEDS TO BE
 NOTED.
  
 7. SHOW SIZE OF WATER SERVICE LINE AND LENGTH.
  
 8. DISPLAY CLOSEST FIRE HYDRANT FROM BUILDING.
  
 9. IF BUILDING REQUIRES FIRE PROTECTION A DCDA
 (DETECTOR CHECK ASSEMBLY) MUST BE INSTALLED. SHOW FDC
 (FIRE DEPARTMENT CONNECTION)
  
 10. NOTE ENGINEER OF RECORD WILL CERTIFY SITE
 CONSTRUCTION TO THE CITY.
  