2011-02-07 11:56:33 | BUILDING PLAN REVIEW |
| PERMIT: 11010505 |
| ADD: 400 COLUMBIA DR |
| CONT: AUTO BUILDERS |
| TEL: (561)722-3956 |
| |
| FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| W/ 2009 FBC SUPPLEMENTS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 2007 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| |
| **BUCK INSPECTION S REQUIRED*** |
| |
| BUILDING PROVISO: |
| BUILDING APPROVED WITH EXCEPTION! |
| REVISION REQUIED PRIOR TO FIRST INSPECTION |
| THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| |
| 1A) SHEET 1 OF 26 INDICATES A "B" EXPOSURE PLEASE |
| REVIEW 2007/2009 FBC-B 1609.4.3 EXPOSURE C. |
| |
| 1B) SHEET 1 OF 26 INDICATES WIND DESIGN PRESSURES TO BE |
| DETERMINED!!!!! PLEASE PROVIDE DESIGN PRESSURES BEFORE |
| FIRST INSPEECTION. |
| |
| 2) SHEET 1 OF 26 PANIC HARDWARE IS EXCLUDED, REVISE |
| PLANS TO SHOW CODE COMPLIANCE BY PROVIDING ANY REQUIRED |
| INFORMATION (SUCH AS OCCUPANCY, OCCUPANT LOAD, AND LIFE |
| SAFETY PLAN), ALSO SEE EXISTING BUILDING CODE 601.1. |
| |