2010-12-16 13:13:42****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
  
 1. OPENING #1, PROVIDE INFORMATION REGARDING THE
 EXISTING WINDOW TO BE REPLACED (TYPE OF WINDOW SUCH AS
 CASEMENT, SINGLE HUNG, ETC.), FBC EB 604.1. PLANS DO
 NOT SHOW CODE COMPLIANCE. IF THIS IS A FULLY
 SPRINKLERED BUILDING, PLEASE NOTE ON THE PLAN.
  
 2. FBC1609.1.2, GLAZING TO MEET SMALL MISSILE IMPACT
 STANDARD OVER 30 FEET.
  
 3. ENGINEER'S PLAN MAKES REFERENCE TO AN EXCEPTION
 WHICH APPLIES ONLY TO ONE AND TWO FAMILY DWELLINGS (SEE
 ITEM 4, SHEET 2 OF 3). IT APPEARS THAT THIS STRUCTURE
 IS A CONDOMINIUM (R2, NOT R3).
  
 PLEASE NOTE THAT IN THE FUTURE PERMITS MAY BE ISSUED
 WITH PROVISO THAT THE PLANS BE REVISED (WITH REVISION
 FEES) TO SHOW CODE COMPLIANCE.
  
  
  
  
  