2010-12-09 13:08:49DENIED BY BUILDING
  
 1) THE APPLICATION IS TO RE-ROOF THE REAR HALF OF A
 GABLE ROOF. THE 2007 FBC EXISTING BUILDING CODE SECTION
 611.1.1 STATES THAT NOT MORE THAN 25 PERCENT OF THE
 TOTAL ROOF AREA OR ROOF SECTION SHALL BE REPLACED
 UNLESS THE ENTIRE ROOFING SYSTEM OR ROOF SECTION
 CONFORMS TO THIS CODE.
  
 2) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE
 ASPHALT SHINGLE ROOF HAS BEEN SUPERSEDED BY NOA
 #09-0825.06. SUBMIT 2 COPIES OF THE CURRENT PRODUCT
 APPROVALS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]