Plan Review Notes For Permit 10110685 |
Permit Number |
10110685 |
|
Review Stop |
P |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2011-01-31 10:39:10 | FBC PLUMBING 2007 REVIEW #2 | | DENIED: | | | | 1. STUDOR VENTS ARE SHOWN ON PLAN. THE DRAINAGE SYSTEM | | FOR THIS BUILDING IS OVER 4 BRANCH INTERVALS ABOVE. | | 917.3.2 A RELIEF VENT WOULD BE REQUIRED. | | | | 2. THE RISER DIAGRAM DOES NOT SHOW WHERE THE SANITARY | | PIPEING IS BEING CONNECTED. THIS AREA OF PLUMBING HAS A | | MIXTURE OF WASTE STACK VENTING AND SOVENT PIPING. | | SOVENT IS AN ENGINEERED SYSTEM. CONNECTIONS DOWNSTREAM | | OF THE DEAERATOR VENT MAY BE MADE WITHOUT | | RE-ENGINEERING THE SYSTEM. CONNECTING INTO THE BUILDING | | DRAIN OR BUILDING DRAIN BRANCHES WOULD ALSO BE | | PERMISSIBLE. | | | | REVIEW BY LARRY WAGNER | | CHIEF PLUMBING INSPECTOR | | (561) 805-6692 | | FAX (561) 653-2692 | | E-MAIL [email protected] | | |
|