2011-01-28 10:41:46 | BUILDING PLAN REVIEW |
| PERMIT:10110685 |
| ADD: 410 EVERNIA ST |
| CONT:BESSENROTH BUILDERS INC/ CBC1255316 |
| TEL: (561)324-4871 |
| |
| FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| W/ 2009 FBC SUPPLEMENTS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 2007 EXISTING BUILDING CODE LEVEL II 701.3 |
| COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| OF THE FLORIDA BUILDING CODE, BUILDING. |
| |
| 2ND REVIEW |
| ACTION: DENIED |
| |
| 1) THERE ARE NO ARCHITECTURAL PLANS SUBMITTED |
| INDICATING SLAB CUT AND REPAIR FOR PLUMBING WASTE PIPES |
| NOR HOW VENT LINES TO BE INSTALLED. |
| |
| 2) THE PLANS FAIL TO PROVIDE VERTICAL ACCESSIBILITY TO |
| THE MEZZANINE LEVEL, THIS BUILDING WAS ORIGINALLY |
| DESIGNED AS RESIDENTIAL NOT REQUIRING |
| VERTICAL ACCESSIBILITY. 11-4.1.6(1)(K)(III). |
| |
| 3) THE CURERNT CONTRACTOR BESSENROTH BUILDERS/ |
| CBC1255316 WILL BE WORKING BEYOND THEIR SCOPE OF |
| LICENSURE. FL S 489.105(B) |
| BUILDING CONTRACTOR??? MEANS A CONTRACTOR WHOSE |
| SERVICES ARE LIMITED TO CONSTRUCTION OF COMMERCIAL |
| BUILDINGS AND SINGLE-DWELLING OR MULTIPLE-DWELLING |
| RESIDENTIAL BUILDINGS, WHICH COMMERCIAL OR RESIDENTIAL |
| BUILDINGS DO NOT EXCEED THREE STORIES IN HEIGHT, AND |
| ACCESSORY USE STRUCTURES IN CONNECTION THEREWITH OR A |
| CONTRACTOR WHOSE SERVICES ARE LIMITED TO REMODELING, |
| REPAIR, OR IMPROVEMENT OF ANY SIZE BUILDING IF THE |
| SERVICES "DO NOT AFFECT THE STRUCTURAL MEMBERS OF THE |
| BUILDING." WE BELIEVE THAT CUTTING THE FIRST FLOOR SLAB |
| AND CORE BORING THE MEZZANINE FLOOR SLAB WOULD BE |
| AFFECTING STRUCTURAL MEMBERS. |
| |
| JIM WITMER C. B. O. |
| COMMERCIAL COMBINATION PLAN REVIEW |
| |
| TEL: (561)805-6715 |
| FAX: (561)805-6731 |
| E-MAIL: [email protected] |
| |