2010-11-18 18:44:25 | PLANNING AND ZONING: **** FAILED **** |
| |
| |
| 1. PLEASE RESPOND TO COMMENTS IN WRITING. |
| |
| 2. PROVIDE PROPOSED BUILDING (STRUCTURE) ON THE SURVEY |
| DEPICTING DIMENSIONS TO ALL PROPERTY LINES. THE REAR |
| SETBACK IS NOT SHOWN. |
| |
| 3. INDICATE SETBACK DIMENSIONS FROM PROPOSED |
| A/C/MECHANICAL EQUIPMENT TO ALL PROPERTY LINES. |
| PURSUANT TO SECTION 94-305(B)(4) OF THE ZLDR: |
| MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET |
| INTO A REQUIRED SETBACK. |
| |
| 4. PURSUANT TO SECTION 94-482 OF THE ZLDR: REQUIRED |
| OFF-STREET PARKING SPACES FOR LESS THAN FOUR |
| RESIDENTIAL DWELLING UNITS SHALL BE LOCATED ON THE |
| PROPERTY ON WHICH THE UNITS ARE CONSTRUCTED. REQUIRED |
| PARKING MAY BE LOCATED IN A FRONT YARD; HOWEVER, THE |
| LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT |
| YARD AREA MUST BE LANDSCAPED. PARKING AREAS LOCATED IN |
| THE FRONT YARD SHALL BE SURFACED WITH A SMOOTH, |
| NONDUSTING SURFACE IN COMPLIANCE WITH SUBSECTION |
| 33-485(E). IT SHALL BE A VIOLATION OF THIS CHAPTER TO |
| PARK ON ANY UNPAVED AREAS AS DESCRIBED IN THIS ARTICLE. |
| |
| PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE |
| SURFACES (EXISTING AND PROPOSED) LOCATED WITHIN THE |
| FRONT YARD (FROM FRONT PROPERTY LINE TO THE FRONT |
| BUILDING FACADE). |
| |
| 5. PROVIDE TOTAL HEIGHT FROM FINISHED FLOOR TO FINISHED |
| ROOF TOP ON SHEET WITH ELEVATIONS. |
| |
| 6. A SEPARATE LANDSCAPE PERMIT IS REQUIRED. CONTACT |
| ROBERT KUSSNER (LANDSCAPE PLANNER) @ 822-1462. |
| |
| SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN SHOWING |
| COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF THE ZLDR. |
| |
| 7. A SEPARATE PERMIT FOR THE PROPOSED DRIVEWAY WILL BE |
| REQUIRED FROM THE ENGINEERING DEPARTMENT THROUGH |
| CONSTRUCTION SERVICES. |
| |
| |
| IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. |
| |
| LINDA MIA FRANCO |
| SENIOR PLANNER |
| PLANNING AND ZONING DEPARTMENT |
| TEL: (561) 822-1443 |