2010-11-08 16:00:452007 FBC W/2009 REVISIONS
  
 DENIED BY PLUMBING
  
 1) BECAUSE THE TDH CALCULATIONS FOR EACH OF THE PUMPS
 HAVE NOT BEEN SUBMITTED, THE MAXIMUM FLOW CAPACITIES OF
 THE PUMPS WILL BE USED TO DETERMINE THE WATER VELOCITY
 IN FEET PER SECOND. THE 1.5 HP POOL PUMP HAS A MAXIMUM
 FLOW RATE OF 120 GPM. THE WATER VELOCITY IN 2-1/2" PIPE
 AT 120 GPM IS 7.84 FEET PER SECOND. THIS EXCEEDS THE 6
 FEET PER SECOND MAXIMUM VELOCITY ALLOWED BETWEEN MAIN
 DRAINS BY FBC R4101.6.3 AND ANSI/APSP 7. PLEASE
 CORRECT.
  
 2) THE DRAIN DETAIL FOR THE POOL PUMP DOES NOT SPECIFY
 THE PIPE SIZE FOR THE SDX SIDE MOUNTED SAFETY DRAIN.
 THE PIPING ISOMETRIC SPECIFIES A 2" SDX SIDE MOUNTED
 DRAIN. PLEASE CORRECT.
  
 3) THE PIPING ISOMETRIC SPECIFIES 2" SIDE MOUNTED
 DRAINS FOR THE WATERFALL AND THE DRAIN DETAIL HAS
 2-1/2" BRANCH PIPING BETWEEN THE MAIN DRAINS.
 ANSI/APSP-7 DEFINES BRANCH PIPING AS MULTIPLE SUCTION
 OUTLET COVERS/GRATES: ALL PIPE AND FITTINGS, INCLUDING
 THE TEE, LOCATED BETWEEN COVERS/GRATES AND THE SINGLE
 SUCTION PIPE FEEDING THE PUMP OR PUMPS. THIS REQUIRES
 THE OUTLETS ON THE MAIN DRAIN SUMPS TO ALSO BE 2-1/2".
 PLEASE CORRECT. NOTE: AT MAXIMUM PUMP FLOW 2-1/2" PIPE
 DOESN'T COMPLY. SEE COMMENT 1.
  