2010-10-06 09:15:38 | PLUMBING PLAN REVIEW |
| PERMIT: 10090078 |
| ADD: 926 SUNSET RD |
| CONT:BRIAN HOLLINGER INC |
| TEL: (561)502-0592 |
| FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| W/ 2009 FBC SUPPLEMENTS |
| |
| SUB- PERMIT FOR MASTER 10090080 |
| DENIED: |
| 1) PLEASE REVIEW COMMENTS BELOW FOR CHANGE OF |
| OCCUPANCY. |
| |
| 2) PLUMBING PERMIT APPLICATION INDICATES REPLACEMENT OF |
| SINK AND TOILET (LOCATION CHANGE) PLEASE SUBMIT |
| DRAWINGS INDICATING THE LOCATION CHANGE AND PLUMBING |
| ISOMETRIC. |
| |
| |
| PLUMBING PLAN REVIEW |
| PERMIT: 10090080- MASTER |
| ADD: 926 SUNSET RD |
| CONT: O/B MARIA GEORGE |
| TEL: (561)718-4600 |
| FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| W/ 2009 FBC SUPPLEMENTS |
| |
| SHED PERMIT: 2578J 18FTX18FT 11-1-84 ORIGINAL PERMIT |
| FOR SHED. |
| |
| THIS REVIEW WILL USE THE 2007 EXISTING BUILDING CODE |
| CHAPTER 9 CHANGE IN OCCUPANCY FOR THE BASIS OF THIS |
| REVIEW. EX. BLDG CODE 901.3 CHANGE OF OCCUPANCY |
| CLASSIFICATION. WHERE THE OCCUPANCY CLASSIFICATION OF A |
| BUILDING CHANGES, THE PROVISIONS OF SECTIONS 902 |
| THROUGH 912 SHALL APPLY. THIS INCLUDES A CHANGE OF |
| OCCUPANCY CLASSIFICATION WITHIN A GROUP AS WELL AS A |
| CHANGE OF OCCUPANCY CLASSIFICATION FROM ONE GROUP TO A |
| DIFFERENT GROUP. |
| |
| EX. BLDG CODE 903.1 GENERAL. BUILDING ELEMENTS AND |
| MATERIALS IN PORTIONS OF BUILDINGS UNDERGOING A CHANGE |
| OF OCCUPANCY CLASSIFICATION SHALL COMPLY WITH SECTION |
| 912. |
| |
| 1ST REVIEW |
| ACTION: DENIED |
| |
| 1) 2007 EX BLDG CODE 910.1 INCREASED DEMAND. WHERE THE |
| OCCUPANCY OF AN EXISTING BUILDING OR PART OF AN |
| EXISTING BUILDING IS CHANGED SUCH THAT THE NEW |
| OCCUPANCY IS SUBJECT TO INCREASED OR DIFFERENT PLUMBING |
| FIXTURE REQUIREMENTS OR TO INCREASED WATER SUPPLY |
| REQUIREMENTS IN ACCORDANCE WITH THE FLORIDA BUILDING |
| CODE PLUMBING , THE INTENT OF THE RESPECTIVE FLORIDA |
| BUILDING CODE, PLUMBING PROVISIONS SHALL BE COMPLIED |
| WITH FOR THE NEW OCCUPANCY. |
| |
| VIDEO TAPE IN VHS THE SANITARY SYSTEM AND SUBMIT TO THE |
| BUILDING DEPARTMENT FOR REVIEW |
| BY CHIEF PLUMBING INSPECTOR FOR CODE COMPLIANCE. |
| |
| PROVIDE A PLUMBING ISOMETRIC OF SANITARY FROM THE VIDEO |
| OF SANITARY SYSTEM. |
| |
| |
| |
| JIM WITMER C. B. O. |
| COMMERCIAL COMBINATION PLAN REVIEW |
| |
| TEL: (561)805-6715 |
| FAX: (561)805-6731 |
| E-MAIL: [email protected] |
| |
| PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE |
| CUSTOMER SERVICE SURVEY AT: |
| WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| |
| CONSTRUCTION SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |