Plan Review Notes For Permit 10080508 |
Permit Number |
10080508 |
|
Review Stop |
E |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2011-02-01 13:18:26 | PROVIDE INTERRUPTING (AIC) CURRENT RATING FOR THE | | ELECTRICAL SERVICE. NEC 110.9 | | CORRECT NOTES TO REFLECT THE CURRENT ELECTRIC CODE: | | 2008 NEC | | PROVIDE AN INTERSYSTEM BONDING BAR AT THE SERVICE. NEC | | 250.94 | | THREE RECEPTACLES REQUIRED IN TWO HALLWAYS. NEC 210.52 | | (H) | | A GFCI PROTECTED OUTLET IS REQUIRED AT THE REAR | | ELEVATION. NEC 210.8, 210.52 (E) (1) | | NOTE ON THE PLAN THE REQUIREMENT FOR TAMPER RESISTANT | | RECEPTACLES. NEC 406.11 | | AT LEAST ONE SWITCH CONTROLLED LIGHTING OUTLET SHALL BE | | PROVIDED ON THE EXTERIOR SIDE OF THE SIDE ENTRANCE. NEC | | 210.70 (A) (2) (B). | | BEDROOM RECEPTACLES MUST BE PROTECTED WITH COMBINATION | | - TYPE AFCI'S. NEC 210.12 (B) | | NOTE ON THE PLAN THAT THE SMOKE DETECTORS ARE TO BE | | INTERCONNECTED. FBC R313.2 | | | | ROBERT LECKY, ELECTRIC PLAN REVIEW, 561-805-6718 | | | | |
|