2010-08-12 12:51:20 | BUILDING APPROVED WITH EXCEPTION! |
| THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| |
| 1) R319.1 LOCATION REQUIRED. PROTECTION FROM DECAY |
| SHALL BE PROVIDED IN THE FOLLOWING |
| LOCATIONS BY THE USE OF NATURALLY DURABLE WOOD OR WOOD |
| THAT IS PRESERVATIVE TREATED IN |
| ACCORDANCE WITH AWPA U1. |
| (5). WOOD SIDING, SHEATHING AND WALL FRAMING ON THE |
| EXTERIOR OF A BUILDING HAVING A |
| CLEARANCE OF LESS THAN 6 INCHES (152 MM) FROM THE |
| GROUND. |
| |
| 2) R703.6.3 WHERE CEMENT PLASTER (STUCCO) IS TO BE |
| APPLIED TO LATH OVER FRAME |
| CONSTRUCTION, MEASURES SHALL BE TAKEN TO PREVENT |
| BONDING BETWEEN THE CEMENT PLASTER |
| AND THE WATER-RESISTIVE BARRIER. A BOND BREAK SHALL BE |
| PROVIDED BETWEEN THE WATER- |
| RESISTIVE BARRIER AND THE CEMENT PLASTER (STUCCO) |
| CONSISTING OF ONE OF THE FOLLOWING: |
| 1. TWO LAYERS OF AN APPROVED WATER-RESISTANT BARRIER |
| MATERIAL; OR |
| 2. ONE LAYER OF AN APPROVED WATER-RESISTANT BARRIER |
| OVER AN APPROVED PLASTIC HOUSE |
| WRAP; OR |
| 3.OTHER APPROVED METHODS OR MATERIALS APPLIED IN |
| ACCORDANCE WITH THE MANUFACTURER'S |
| INSTALLATION INSTRUCTIONS. |
| |
| |