Plan Review Notes
Plan Review Notes For Permit 10070578
Permit Number 10070578
Review Stop B
Sequence Number 1
Notes
Date Text
2010-07-22 19:41:09****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED,
 FAC9B72. NOA #09-0518.09 IS EXPIRED (YKK 35H OUTSWING
 DOOR).
  
 2. THIS PERMIT WILL BE ISSUED WITH THE PROVISO THAT
 EXISTING EXITING IS NOT AFFECTED, FBC CHAPTER 10.
 EXISTING DOOR CONFIGURATION REMAINS THE SAME PER
 CONTRACTOR. IF THIS IS NOT THE CASE, PROVIDE A LIFE
 SAFETY PLAN SHOWING COMPLIANCE WITH FBC CHAPTER 10 AND
 LIFE SAFETY 101 (FIRE REVIEW REQUIRED).
  
 3. ELECTRIC PERMIT REQUIRED.
  
 4. DOOR DETAIL O IS SHOWN WITH APPROX. 37"X 80" D.L.O.
 MAX DAYLIGHT OPENING IS LIMITED TO 33 7/8" X 32", SEE
 SHEET 1 OF STANLEY NOA #09-1230.01. THIS CAN BE A
 REDLINE ITEM.
  
 5. A PERMIT APPLICATION SIGNED BY THE QUALIFIER WILL BE
 REQUIRED PRIOR TO RELEASE OF PERMIT.
  
  