2011-02-03 11:03:12 | BUILDING PLAN REVIEW |
| PERMIT: 10070561 |
| ADD: 716 NEY YORK ST |
| CONT: TO BE DETERMINED |
| CONTACT: PENE LATHAM |
| TEL: (561)832-1500 |
| |
| FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| W/ 2009 FBC SUPPLEMENTS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 2ND REVIEW |
| ACTION: DENIED |
| |
| NOTE SHEET 1.1 INDICATES A TWO STORY TO BE REMODELED |
| THERE ARE NO OTHER REFERENCES IN EITHER THIS PLAN NOR |
| PERMIT APPLICATION AND WILL NOT BE PART OF WORK TO BE |
| COMPLETED UNDER THIS PERMIT . |
| |
| 1) EITHER A CONTRACTOR OR OWNER/ BUILDER WILL BE |
| REQUIRED TO SIGN ON TO THE PERMIT APPLICATION. |
| |
| 2) COMPLIED, TWO SETS OF PLANS. |
| |
| 3) SEMI-COMPLIED. THE PLANS ARE DESIGNED BY RICHARD |
| BOYETTE A FL PE, PE# 42485, PLANS ARE NOT SIGNED NOR |
| SEALED. |
| PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS |
| PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR |
| PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE |
| DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. |
| FL ADMIN CODE 61G15-23.002 ENGINEERS |
| |
| |
| |
| 4) NO PRODUCT APPROVALS WERE SUBMITTED. 106.3.3 PRODUCT |
| APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE |
| DCA RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN |
| WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| FOR JURISDICTIONAL APPROVAL. |
| |
| 5) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, |
| PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING |
| REPORTS ARE AS FOLLOWS: |
| 5A) WINDOWS RULE 9B-72(31) (B) |
| SINGLE HUNG |
| CASEMENT |
| 5B) EXTERIOR DOORS RULE 9B-72(31) (A) NEW RULE 9N-3 |
| 5C) ROOF ASSEMBLIES RULE 9B-72(31) (D) NEW RULE 9N-3 |
| 5D) STORM SHUTTERS/ PANELS 9B-72(31)(E) NEW RULE 9N-3 |
| |
| PLEASE NOTE IF THE CONTRACTOR DOES NOT SUPPLY THE |
| PRODUCT APPROVALS BEFORE TIME OF ISSUANCE, THESE ITEMS |
| CAN BE A BUILDING PROVISO: WHICH MEANS THE PRODUCT |
| APPROVALS CAN BE BROUGHT IN AFTER ISSUANCE BUT WILL BE |
| CONSIDERED A REVISION WITH FURTHER REVIEW AND |
| ASSOCIATED FEES. THE DESIGN PRESSURES INDICATED ON |
| SHEET 5.1 ARE CORRECT. |
| |
| 6) 2ND REQUEST, SHEET 3.1 IN THE DESIGN PARAMETERS AND |
| CODE REFERENCES, BOTH MAKE REFERENCES TO THE 2004 FBC, |
| PLEASE REVISE TO THE 2007 FBC WITH 2009 SUPPLEMENTS. |
| PLEASE ALSO INCLUDE UNDER THE 2007 EXISTING BUILDING |
| CODE COMPLIANCE WITH SECTION 401.4 A DESIGN |
| PROFESSIONAL OR AN OWNER MUST ELECT ONE OR A |
| COMBINATION OF LEVELS OF ALTERATION PURSUANT TO |
| SECTIONS 403, 404 AND 405 OF THIS CODE. |
| |
| 7-8) COMPLIED. |
| |
| 9) RESIDENTIAL: ENERGY CODE 2007 SUPPLEMENTS. |
| N1100.0.3 ADDITIONS. ADDITIONS TO EXISTING RESIDENTIAL |
| BUILDINGS SHALL BE CONSIDERED NEW BUILDING CONSTRUCTION |
| AND SHALL COMPLY WITH THE REQUIREMENTS OF EITHER METHOD |
| A OR B AS APPLICABLE. ADDITIONS THAT ARE UNABLE TO |
| COMPLY WITH CODE REQUIREMENTS FOR THE ADDITION ALONE |
| MAY COMPLY WITH THE CODE BY BRINGING THE ENTIRE |
| BUILDING INTO COMPLIANCE WITH SECTION N1100.A.5.2. |
| N1100.0.4 RENOVATIONS. RENOVATED BUILDINGS SHALL, WHEN |
| APPLICABLE (SEE SECTION N1100.7.3), MEET THE |
| PRESCRIPTIVE REQUIREMENTS CONTAINED IN METHOD B FOR |
| INSULATION, HVAC SYSTEMS, WATER HEATING SYSTEMS AND |
| EXTERIOR ENVELOPE FOR THOSE COMPONENTS BEING |
| RETROFITTED OR REPLACED. |
| |
| 10) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| JIM WITMER C. B. O. |
| COMMERCIAL COMBINATION PLAN REVIEW |
| |
| TEL: (561)805-6715 |
| FAX: (561)805-6731 |
| E-MAIL: [email protected] |
| |