2010-09-21 09:59:59 | BUILDING PLAN REVIEW |
| PERMIT: 08010251/ REV 10070389 |
| ADD: 2223 PALM BEACH LAKES # 101 |
| CONT: CONFORT BUILDERS |
| TEL: (561)662-2455 |
| |
| FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| W/ 2009 FBC SUPPLEMENTS |
| * WEST PALM BEACH AMENDMENTS |
| |
| SEPTEMBER 21/2010 |
| 3RD REVIEW |
| ACTION: DENIED |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| YOUR ANTICIPATED COOPERATION. |
| |
| |
| 1A)SEMI-COMPLIED. PLEASE PROVIDE A SITE PLAN WITH THE |
| NEW EGRESS DOORS AT SIDE OF BUILDING INDICATING THE |
| ACCESSIBLE PATH TO THE PUBLIC WAY. 11-4.1.3(8)(A)(II) |
| ACCESSIBLE ENTRANCES MUST BE PROVIDED IN A NUMBER AT |
| LEAST EQUIVALENT TO THE NUMBER OF EXITS REQUIRED BY THE |
| APPLICABLE BUILDING/FIRE CODES. THE EXTERIOR DOORS FROM |
| HALL'S 3 & 4 ARE MISSING ON THE DEVELOPED PLAN DATED |
| 8/23/2010. WITH THE ACCORDIAN DOORS IN THE CLOSED |
| POSITION THESE ROOMS ALL HAVE AN OCCUPANT LOAD GREATER |
| THAN 50 OCCUPANTS REQUIRING 2 MEANS OF EGRESS. FBC-B |
| 1015.1(1). |
| |
| THE PLANS ARE NOT CONSISTENT IN INDICATING THE NEW |
| RECESSED EXIT ENCLOSURES: |
| A-1 SCOPE OF WORK THE NEW RECESSED EXIT ENCLOSURES ARE |
| MISSING |
| A-3 THE LIFE SAFETY PLAN THEY ARE MISSING AND THE |
| ADDITIONAL EXIT SIGNAGE. |
| A-4 THE REFLECTED CEILING PLAN THE ENCLOSURES ARE |
| MISSING AND EXIT SIGNAGE , |
| NOTE NO STRUCTURAL INFORMATION WAS PROVIDED FOR THE NEW |
| RESSED ENCLOSURE, PRODUCT APPROVAL FOR DOOR |
| E-1 ALSO IS EFFECTED WITH THE ADDITIONAL EXIT LIGHT |
| REQUIREMENTS. |
| |
| 1B-G-I) COMPLIED. |
| |
| 1J) SECOND REQUEST,PLANS ALSO INDICATE ON A-2 A NEW |
| STOREFRONT DOOR AND WINDOW SYSTEM, PLEASE PROVIDE WIND |
| DESIGN CRITERIA: |
| |
| 1609.6.2 WIND DESIGN PROCEDURES |
| 1J)(1) COMPLIED. |
| |
| 1J)(2)COMPLIED. |
| |
| 1J)(3) SECOND REQUEST, AN EXPOSURE CATEGORY SHALL BE |
| DETERMINED IN ACCORDANCE WITH 1609.4. SHEET A-1 |
| (8/23/10) INDICATES A "B" EXPOSURE, PLEASE REVIEW |
| SECTION |
| FBC-B 1609.4.3 EXPOSURE C THIS EXPOSURE SHALL ALSO |
| APPLY TO ANY BUILDING LOCATED WITHIN EXPOSURE B-TYPE |
| TERRAIN WHERE THE BUILDING IS WITHIN 100 FEET |
| HORIZONTALLY IN ANY DIRECTION OF OPEN AREAS OF EXPOSURE |
| C-TYPE TERRAIN THAT EXTENDS MORE THAN 600 FEET (182.9 |
| M) AND WIDTH GREATER THAN 150 FT. IN THE UPWIND |
| DIRECTION. |
| |
| 1J)(4) SINCE THE EXPOSURE "C" HAS ADJUSTMENT FACTOR |
| PLEASE REVIEW PRESSURES. PROVIDE THE MEAN ROOF HEIGHT. |
| A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * SHALL |
| BE DETERMINED FROM TABLE 1609.6.2.1(4) THEDESIGNER OF |
| RECORD IS APPERANTLY LOOKING FOR END ZONE CONDITIONS |
| "WORST CASE" WITH PRESSURES OF -60.88 (A-1) |
| THE SUBMITTED PRODUCT APPROVAL FOR THE FRONT DOOR ARE |
| LOW AT +/-55 PSF. |
| |
| 1K) SECOND REQUEST, WILL NEED TO BE RE-REVIEWED FOR |
| EXPOSURE "C" FACTORS. NOTE NO PRODUCT APPROVALS WERE |
| SUBMITTED. |
| FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, PROVIDE 2 |
| COPIES, |
| 3 IF THRESHOLD OR RESIDENT INSPECTOR OF PRODUCT TESTING |
| REPORTS, MISSING REPORTS ARE AS FOLLOWS: |
| 1) EXTERIOR DOORS FRONT ENTRY |
| 2) EXERIOR SIDE DOORS- MISSING |
| |
| 1L)2ND REQUEST. 106.3.3 PRODUCT APPROVALS. THOSE |
| PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9B-72 |
| SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| JURISDICTIONAL APPROVAL. |
| |
| 1M) SECOND REQUEST, NEW EXTERIOR OPENINGS PLEASE |
| PROVIDE DETAILS ON THE MWFRS CONTINIOUS LOAD PATH. WITH |
| REQUEST IS NOW FOR THE NEW EXIT RECESS FOR BANQUET |
| HALL # 3& 4. |
| |
| 1N)COMPLIED. |
| |
| 1O) SECOND REQUEST, PLEASE PROVIDE MANUFACTURERS |
| DETAILS ON THE FOLDING PARTITION AS TO INSTALATION, |
| 106.1.2 ADDITIONAL INFORMATION REQUIRED. IT IS NOT |
| KNOWN IF THESE LOADS WILL BE IMPOSED ONTO THE ROOF |
| CEILING ASSEMBLY OR NOT? AND WHAT THESE LOADS MAY BE, |
| THIS ITEM CAN BE A BUILDING PROVISO: AND BE SUBMITTED |
| AFTER THTE PERMIT ISSUANCE ONCE REVIEWED BY THE DESIGN |
| PROFESSIONAL. |
| |
| 1P) COMPLIED. |
| |
| 1R) COMPLIED. |
| |
| 1S) COMPLIED. |
| |
| 2) COMPLIED. |
| |
| 3) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. |
| A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| JIM WITMER C. B. O. |
| COMMERCIAL COMBINATION PLAN REVIEW |
| |
| TEL: (561)805-6715 |
| FAX: (561)805-6731 |
| E-MAIL: [email protected] |
| |
| PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE |
| CUSTOMER SERVICE SURVEY AT: |
| WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| |
| CONSTRUCTION SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |