Plan Review Notes For Permit 10070193 |
Permit Number |
10070193 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2010-07-26 14:59:26 | FBC 2007 | | PLUMBING PLAN REVIEW | | DENIED | | | | NOT ENOUGH INFORMATION FOR REVIEW. | | 106.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS: | | 13. PLUMBING RISER DIAGRAMS | | | | 1. CAN NOT TELL IF NEW TUBS ARE CONNECTING INTO A WET | | VENT. ONLY BATHROOM FIXTURES MAY CONNECT INTO A WET | | VENT. | | | | 2. IS WASHING MACHINE NEW OR EXISTING? SEE ABOVE FOR | | WET VENTING | | | | 3. PROVIDE PLANS PREPARED BY A DESIGN PROFESSIONAL, | | FS481. | | | | REVIEW BY LARRY WAGNER | | CHIEF PLUMBING INSPECTOR | | (561) 805-6692 | | FAX (561) 653-2692 | | E-MAIL [email protected] | | |
|