2010-07-06 12:10:55RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST.
 2007 FBC WITH 2009 REVISIONS.
  
 1- SPECIFY WHICH APPROVED ASSEMBLY OF NOA 08-0227.07
 SUBMITTED IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE
 WITH THE DESIGN PRESSURES OF SEC. R301 OF 2007 FLORIDA
 RESIDENTIAL CODE.
  
 2- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR
 NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS
 REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA
 SUBMITTED. THIS CALCULATIONS ARE REQUIRED TO MEET THE
 DESIGN PRESSURES OF SEC. R301. DESIGN PROFESSIONAL
 DOING THE RAS 117 CALCULATIONS TO TAKE INTO
 CONSIDERATION THAT ACCORDING TO THE 2009 REVISIONS THIS
 BUILDING IS IN EXPOSURE "C".
  
 ***NOTE: APPROVED ASEMBLIES THAT ARE LIMITED BY GENERAL
 LIMITATION #9 CAN'T BE USED IN THIS BUILDING BECAUSE
 THIS LIMITATION DOESN'T ALLOW NAIL ENHANCING. SEE LAST
 PAGE OF NOA SUBMITTED.
  