2010-07-08 15:48:56ZONING PLAN REVIEW
  
 PERMIT NO.: 10070049
 ADDRESS: 1102 19TH STREET
 CONTRACTOR/CONTACT: DREW LOCHER
 TELEPHONE NO.: 407.947.6450
 SCOPE OF REVIEW: NEW SINGLE FAMILY HOME???ALTHEA MODEL
 MASTER FILED.
  
 REVIEW STATUS: FAILED
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1) THE SITE PLAN SHALL NOTE THE LOCATION OF ALL
 EXTERIOR STAIRS AND SHALL BE DIMENSIONED. PURSUANT TO
 SECTION 94-305(A)(7) OF THE ZLDRS, STEPS WHICH ARE
 THREE (3) FEET OR LESS ABOVE GRADE SHALL NOT ENCROACH
 INTO ANY REQUIRED SETBACK TO A POINT NO CLOSER THAN TWO
 (2) FEET TO THE PROPERTY LINE.
  
 2) THE SITE PLAN SHALL NOTE THE LOCATION OF ALL
 MECHANICAL EQUIPMENT. PURSUANT TO SECTION 94-305(A)(4)
 OF THE ZLDRS, MECHANICAL EQUIPMENT SHALL NOT ENCROACH
 MORE THAN FOUR (4) FEET INTO ANY REQUIRED SETBACK.
  
 3) PLEASE PROVIDE THE DIMENSIONS OF ALL WALKWAYS,
 DRIVEWAYS, ETC. PURSUANT TO SECTION 94-482(A) OF THE
 ZLDRS, A MINIMUM OF 75%, OR 1,000 SQUARE FEET OF THE
 FRONT YARD, WHICHEVER IS LESS, SHALL REMAIN AS
 LANDSCAPING. THERE DOES NOT APPEAR TO BE ANY PROBLEM
 WITH THIS, JUST PLEASE NOTE THE DIMENSIONS AS
 VERIFICATION.
  
 4) PLEASE INDICATE THE DIMENSION OF THE ROOF OVERHANGS.
 THE CONSTRUCTION PACKAGE FOR THE BUILDING INDICATES
 THAT ROOF OVERHANGS MAY VARY, BUT ARE TYPICALLY 12
 INCHES. ARE THE TYPICAL OVERHANGS BEING USED OR HAVE
 THEY BEEN MODIFIED. PLEASE PROVIDE CLARIFICATION, AS
 SECTION 94-305(A)(2) OF THE ZLDRS PROVIDES THAT
 STRUCTURAL INTRUSIONS SHALL NOT EXTEND ANY FURTHER THAN
 THREE (3) FEET INTO A REQUIRED SETBACK.
  
 PRIOR TO THE FIRST INSPECTION, THE FOLLOWING SHALL BE
 PROVIDED:
  
 1) A SITE-SPECIFIC LANDSCAPE PLAN INDICATING COMPLIANCE
 WITH ARTICLE XIV OF THE CITY???S ZLDRS???THIS PLAN DOES
 NOT NEED TO BE SIGNED/SEALED.
  
 2) A SITE-SPECIFIC IRRIGATION PLAN.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 PLANNING AND ZONING DEPARTMENT
 401 CLEMATIS STREET - P.O. BOX 3366
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1435
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.CITYOFWPB.COM
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved