Plan Review Notes
Plan Review Notes For Permit 10060739
Permit Number 10060739
Review Stop B
Sequence Number 1
Notes
Date Text
2010-06-28 12:44:52RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW CHECKLIST.
 2007 FBC WITH 2009 REVISIONS.
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9B-72 FOR FLAT ROOF TO BE INSTALLED.
  
 2- CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY AND BASE
 SHEET FASTENING OPTION IS GOING TO BE INSTALLED TO
 VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC.
 R301 OF 2007 FLORIDA RESIDENTIAL CODE.
  
 3- PROVIDE RAS 117 CALCULATIONS (2 COPIES) FOR NAIL
 ENHANCING AT PERIMETER AND CORNER AREAS AS REQUIRED BY
 GENERAL LIMITATION #7.
 A) IF PRODUCT APPROVAL SUBMITTED REQUIRES RAS 117
 CALCULATIONS TO BE SIGNED AND SEALED, THEN PROVIDE
 SIGNED AND SEALED RAS 117 CALCULATIONS (2 COPIES). SEE
 GENERAL LIMITATION #7 ON LAST PAGE OF NOA SUBMITTED.
  
 B) ACCORDING TO 2009 REVISIONS THIS BUILDING IS LOCATED
 ON EXPOSURE "C". TAKE THIS INTO CONSIDERATION WHEN
 DOING THE RAS 117 CALCULATIONS.
  
 4- OWES $67.67 FOR UPDATED VALUATION AS REQUIRED BY
 SEC. 108.3 OF CITY AMENDMENTS TO FBC.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved