2010-08-09 16:13:512007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) THE INSTALLATION SCHEDULE FOR THE STORM PANELS
 INDICATE THAT THE H-HEADER AT THE TOP IS TO BE ANCHORED
 TO BLOCK. THE PRODUCT APPROVAL REQUIRES POURED CONCRETE
 FOR THIS INSTALLATION. SEE SHEET 2 OF 9 AND THE TABLE
 ON SHEET 5 OF 9. PLEASE CORRECT.
  
 2) PROVIDE A DETAIL OF THE COLUMN CAP AT THE TOP OF THE
 NEW ALUMINUM COLUMN ON THE PLAN.
  
 3) SPECIFY THE CONNECTORS THAT WILL BE USED TO ANCHOR
 THE RAFTERS AT THE LAUNDRY ROOM AND PORCH.
  
 4) SPECIFY THE EXTERIOR WALL COVERING THAT WILL BE USED
 ON THE LAUNDRY ROOM ON THE PLANS. SHOW COMPLIANCE WITH
 FBC R319 FOR CLEARANCE TO GROUND AND FBC R704.1 FOR
 CLEARANCE FOR TERMITE INSPECTION.
  
 5) THE STRUCTURE IS LOCATED IN A 140 MPH WIND SPEED AND
 EXPOSURE CATEGORY C. SPECIFY THE WIND SPEED AND
 EXPOSURE CATEGORY ON THE PLANS.
  