Notes |
Date |
Text |
2010-07-26 18:01:20 | ****CORRECTIONS**** | | ****DCA MODEL FMP4586C***MFGR MODEL ALTHEA*** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. AS DISCUSSED, PLEASE INCLUDE THE STAIR DETAIL WITH | | THE MASTER PERMITS. PLEASE REVISE THE DETAIL TO | | INCLUDE: | | | | FBC311.5.3.2, THE SUM OF TWO RISERS AND A TREAD TO | | EQUAL NOT LESS THAN 24" NOR MORE THAN 25". | | | | SPECIFY STRINGER ATTACHMENT, TOP AND BOTTOM. | | | | SPECIFY GUARD OPENING LIMITATIONS FBC R312.2 AND STAIR | | RAIL HEIGHT FBC R 311.5.6.1. | | | | 2. PROVIDE AN ORIGINAL UNIT CONNECTION DETAIL, AND HAVE | | THE SECOND SHEET SIGNED AND SEALED. FS471. | | | | | | | | |
|